D-Link DSN-5000-10 Hardware Reference Guide for DSN-5000-10 - Page 18

Front Panel Components

Page 18 highlights

2.1 Front Panel Components The front of the DSN-5000 series primary array enclosure has the following components (see Figure 2-1  Enclosure LEDs - four enclosure LEDs at the right side of the front panel provide status information about the DSN-5000 series primary array enclosure. For a description of these LEDs, see Table 2-1.  Drive slots - the front panel provides access to 12 drive slots. The drive slots are arranged in four columns of 3 slots.  Drive carriers - drives are mounted on a drive carrier. Drive carriers have a push-button lever for installing and removing drives, and three status LEDs (see Figure 2-2 and Table 2-2). Each carrier has a corresponding drive slot number (see Figure 2-3). Filler panels must be installed in all drive slots that are not occupied by a drive. Drive Carrier (see Figure 2-2 for Close-up View) Drive Slots Figure 2-1. Front View of the DSN-5000 series Primary Array Lever Release Button Enclosure LEDs Drive Status LEDs Figure 2-2. Close-up View of the Lever Release Button and Status LEDs on a Drive Carrier Figure 2-3. Drive Numbers on the Primary Array 10 Chapter 2 DSN-5000 Series Primary Array Layout

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

10
Chapter 2
DSN-5000 Series Primary Array Layout
2.1
Front Panel Components
The front of the DSN-5000 series primary array enclosure has the following components (see
Figure 2-1
Enclosure LEDs
- four enclosure LEDs at the right side of the front panel provide status
information about the DSN-5000 series primary array enclosure. For a description of
these LEDs, see Table 2-1.
Drive slots – the front panel provides access to 12 drive slots. The drive slots are
arranged in four columns of 3 slots.
Drive carriers - drives are mounted on a drive carrier. Drive carriers have a push-button
lever for installing and removing drives, and three status LEDs (see Figure 2-2 and Table
2-2). Each carrier has a corresponding drive slot number (see Figure 2-3). Filler panels
must be installed in all drive slots that are not occupied by a drive.
Figure 2-1. Front View of the DSN-5000 series Primary Array
Figure 2-2. Close-up View of the Lever Release Button and Status LEDs on a Drive Carrier
Figure 2-3. Drive Numbers on the Primary Array
Enclosure
LEDs
Drive Slots
Drive Carrier
(see
Figure 2-2
for
Close-up View)
Drive Status LEDs
Lever Release Button