Gateway E-9525R Gateway E-9525R Server User Guide - Page 52
then push it in the direction of the arrow to lock it into place 4., Follow the instructions
View all Gateway E-9525R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
CHAPTER 4: Installing Components 4 Lift the release tab (1) (similar on both fan cages), then push the fan cage in the direction of the arrow (2) to unlock it from the chassis. 5 Lift the fan cage (3) and unplug the connectors from it, then remove the cage from the chassis. Important Make sure that the arrows on top of the fans indicating airflow point to the back of the chassis. The fan cable should exit the fan module toward the back of the chassis. 6 Install system fans as necessary in the new system fan cage. 7 Connect the cables you removed to the new system fan cage, then align the cage with the standoffs in the chassis. 8 Place the new system fan cage and fans onto the locking tabs (standoffs) in the chassis (3), then push it in the direction of the arrow to lock it into place (4). 9 Replace the fan duct into the chassis. 10 Follow the instructions in "Closing the server case" on page 32. 46