HP 353803-B22 HP StorageWorks 1000 Modular Smart Array maintenance and service - Page 44
For Cache Error, Cache Disabled
UPC - 808736781619
View all HP 353803-B22 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
Message 67 CACHE HARDWARE TEMPORARILY DISABLED Type Informational 68 OBSOLETE CACHE DATA DELETED Informational 69 CACHE BATTERIES Informational LOW, RECHARGING 70 CACHE DISABLED NO CONFIGURATION Informational 71 SYSTEM HALTED FOR CACHE ERROR Error Description Action The cache memory hardware has temporarily been disabled, typically because the battery is not charged or a capacity expansion operation is occurring. The cache automatically enabled once the condition has been corrected. Old data that no longer belongs to any current configured volumes was found in the cache memory at power up. This data has been deleted. This typically happens if cache modules are moved between array controllers. The batteries on the cache module are low and are being recharged. The cache has not been configured and is disabled. The cache is configured using the Array Configuration Utility (ACU) or MSA Command Line Interface (MSA-CLI). This message is displayed upon a no response to message 72 CACHE ERROR IGNORE? =YES . See the information for message 72 CACHE ERROR. 44 LCD panel and message descriptions