HP HP12C hp 12c_user's guide_English_E_HDPMBF12E44.pdf - Page 181
Error Conditions
UPC - 882780792104
View all HP HP12C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 181 highlights
Appendix C Error Conditions Some calculator operations cannot be performed under certain conditions (for example, z when x = 0). If you attempt such an operation under these conditions, the calculator will display the word Error followed by a digit, 0 through 9. Listed below are operations that cannot be performed under the conditions specified. The symbols x and y represent the number in the X- and Y-registers, respectively, when the operation key is pressed. Error 0: Mathematics Operation Condition z x = 0 y x = 0 r x < 0 ° x ≤ 0 q y = 0 and x ≤ 0 à Z ?z(0 through 4) e y < 0 and x is noninteger. y = 0 y = 0 x = 0 x is noninteger x < 0 181 File name: hp 12c_user's guide_English_HDPMBF12E44 Printered Date: 2005/7/29 Page: 181 of 209 Dimension: 14.8 cm x 21 cm