HP HP12C hp 12c_user's guide_English_E_HDPMBF12E44.pdf - Page 182
Error 1: Storage Register Overflow, Error 2: Statistics, Error 3: IRR, Error 4: Memory
UPC - 882780792104
View all HP HP12C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 182 highlights
182 Appendix C: Error Conditions Error 1: Storage Register Overflow Operation ?+(0 through 4) ?-(0 through 4) ?§(0 through 4) ?z(0 through 4) A Condition Magnitude of result is greater than 9.999999999×1099. Error 2: Statistics Operation Ö v R Q R~ Q~ Condition n (number in R ) = 0 1 Σx = 0 n = 0 n = 1 nΣx2 - (Σx)2< 0 nΣy2 - (Σy)2< 0 n = 0 nΣx2 - (Σx)2 = 0 n = 0 nΣy2 - (Σy)2 = 0 [nΣx2 - (Σx)2][nΣy2 - (Σy)2] ≤ 0 Error 3: IRR Refer to Appendix B. Error 4: Memory z Attempting to enter more than 99 program lines. z Attempting to i to a program line that does not exist. z Attempting storage register arithmetic in R5 through R9 or R.0 through R.9. File name: hp 12c_user's guide_English_HDPMBF12E44 Printered Date: 2005/7/29 Page: 182 of 209 Dimension: 14.8 cm x 21 cm