HP Scitex LX850 HP Scitex LX850 & LX820 Printers: User's Guide - English - Page 107

Air supply requirements (pneumatic spindle), Air pressure supply

Page 107 highlights

Specifications Table 7-8 Printer's single-phase line specifications (continued) High-voltage systems Low-voltage systems Maximum load current (per phase) 10 A 1 Japan may have input frequencies of 50 Hz or 60 Hz 10 A In Japan only, a bi-phase power supply is required, operating at 200 V ac. The printer requires two branch circuit breakers: one for the single-phase line and one for the threephase line. Table 7-9 Three-phase circuit breaker specifications High-voltage systems Low-voltage systems Input voltage (line to line) 3 × 380-415 V~ (-10%+6%) 3 × 200-220 V~ (±10%) Input frequency 50 Hz 60 Hz Three-phase branch circuit breaker 3 poles, 40 A 3 poles, 63 A Table 7-10 Single-phase circuit breaker specifications High-voltage systems Input voltage (line to line) 200-240 V~ (-10%+6%) Input frequency 50 Hz Single-phase branch circuit breaker 2 poles, 20 A Low-voltage systems 115-127 V~ (±10%) (Japan 200 V~) 60 Hz 2 poles, 20 A Air supply requirements (pneumatic spindle) Air pressure supply The pneumatic spindle requires an air compressor or a pressurized air line, not supplied with the printer. TIP: You are recommended to use a pressure gauge that indicates the pressure in bars. Table 7-11 Air supply specifications Air pressure Minimum airflow Lubricator Air filter (recommended) Regulator (required) 5.5 bar (80 psi) Recommendation: 30 l/min Not recommended Recommendation: 5 μm, auto-drain, 99.97% coalescing efficiency Regulator with pressure gauge ENWW Air supply requirements (pneumatic spindle) 103

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114

Table 7-8
Printer's single-phase line specifications (continued)
High-voltage systems
Low-voltage systems
Maximum load current (per phase)
10 A
10 A
1
Japan may have input frequencies of 50 Hz or 60 Hz
In Japan only, a bi-phase power supply is required, operating at 200 V ac.
The printer requires two branch circuit breakers: one for the single-phase line and one for the three-
phase line.
Table 7-9
Three-phase circuit breaker specifications
High-voltage systems
Low-voltage systems
Input voltage (line to line)
3 × 380–415 V~ (-10%+6%)
3 × 200–220 V~ (±10%)
Input frequency
50 Hz
60 Hz
Three-phase branch circuit breaker
3 poles, 40 A
3 poles, 63 A
Table 7-10
Single-phase circuit breaker specifications
High-voltage systems
Low-voltage systems
Input voltage (line to line)
200–240 V~ (-10%+6%)
115–127 V~ (±10%) (Japan 200 V~)
Input frequency
50 Hz
60 Hz
Single-phase branch circuit breaker
2 poles, 20 A
2 poles, 20 A
Air supply requirements (pneumatic spindle)
Air pressure supply
The pneumatic spindle requires an air compressor or a pressurized air line, not supplied with the
printer.
TIP:
You are recommended to use a pressure gauge that indicates the pressure in bars.
Table 7-11
Air supply specifications
Air pressure
5.5 bar (80 psi)
Minimum airflow
Recommendation: 30 l/min
Lubricator
Not recommended
Air filter (recommended)
Recommendation: 5
μ
m, auto-drain, 99.97% coalescing
efficiency
Regulator (required)
Regulator with pressure gauge
ENWW
Air supply requirements (pneumatic spindle)
103
Specifications