HP StorageWorks 2/16V HP StorageWorks Fabric OS 5.3.x administrator guide (569 - Page 315

Port mirroring, Name Server

Page 315 highlights

• VE_Port-Functions somewhat like an E_Port, but terminates at the switch and does not propagate fabric services or routing topology information from one edge fabric to another. • VEX_Port-A type of VE_Port that connects a Fibre Channel router to an edge fabric. From the point of view of a switch in an edge fabric, an VEX_Port appears as a normal VE_Port. It follows the same Fibre Channel protocol as other VE_Ports. However, the router terminates VEX_Ports rather than allowing different fabrics to merge as would happen on a switch with regular VE_Ports. The FCP auto discovery process enables private storage devices that accept PRLI to communicate in a fabric. If device probing is enabled, the embedded port PLOGIs and attempts a PRLI into the device to retrieve information to enter into the Name Server. This enables private devices that do not FLOGI but accept PRLI to be entered in the Name Server and receive full fabric citizenship. Private devices that accept PRLI represent a majority of storage targets. Private hosts require the QuickLoop feature, which is not available in Fabric OS v4.0.0 or later. A fabric-capable device will implicitly register information with Name Server during a FLOGI. These devices will typically register information with the Name Server before querying for a device list. The embedded port will still PLOGI and attempt PRLI with these devices. You can view the Name Server table in Web Tools by clicking Name Server in the fabric toolbar. Refer to the Web Tools Administrator's Guide for more information. Port mirroring Port mirroring lets you configure a switch port as an analyzer port to mirror a specific source port and destination port traffic passing though any switch port. This is a useful way to troubleshoot without bringing down the host and destination links to insert an inline analyzer. Port mirroring captures traffic between two devices. It mirrors only the frames containing the SID/DID to the mirror port. Because of the way it handles mirroring, a single mirror port can mirror multiple mirror connections. This also means that the port cannot exceed the maximum bandwidth of the mirror port. Attempts to mirror more traffic than available bandwidth result in the port mirror throttling the SID/DID traffic so that traffic does not exceed the maximum available bandwidth. Port mirroring is supported between VE_ports (VE_Port to VE_Port) with FCIP and no routing, and over VEx _Ports and Ex_Ports. The mirror port can be any port located on the same switch as the source identifier (SID). Use port mirroring to detect missing frames, which might occur with zoning issues or hold timeouts, capture protocol errors, and capture ULP traffic (SCSI/FICON). This feature cannot be used on embedded switch traffic. Port mirroring is only available using the FOS 5.2.x CLI and is not available through Web Tools. For a complete list of port mirroring commands, see the Fabric OS Command Reference Manual. In order to ensure proper failover in HA configurations, both the active and the standby control processors (CP) must have firmware version 5.2 installed and running. If the OS on the standby CP does not support mirroring, failing over the standby CP could cause the HA failover to fail. Fabric OS 5.3.0 administrator guide 327

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324
  • 325
  • 326
  • 327
  • 328
  • 329
  • 330
  • 331
  • 332
  • 333
  • 334
  • 335
  • 336
  • 337
  • 338
  • 339
  • 340
  • 341
  • 342
  • 343
  • 344
  • 345
  • 346
  • 347
  • 348
  • 349
  • 350
  • 351
  • 352
  • 353
  • 354
  • 355
  • 356
  • 357
  • 358
  • 359
  • 360
  • 361
  • 362
  • 363
  • 364
  • 365
  • 366
  • 367
  • 368
  • 369
  • 370
  • 371
  • 372
  • 373
  • 374
  • 375
  • 376
  • 377
  • 378
  • 379
  • 380
  • 381
  • 382
  • 383
  • 384
  • 385
  • 386
  • 387
  • 388
  • 389
  • 390
  • 391
  • 392
  • 393
  • 394
  • 395
  • 396
  • 397
  • 398
  • 399
  • 400
  • 401
  • 402
  • 403
  • 404
  • 405
  • 406
  • 407
  • 408
  • 409
  • 410
  • 411
  • 412
  • 413
  • 414
  • 415
  • 416
  • 417
  • 418
  • 419
  • 420
  • 421
  • 422
  • 423
  • 424
  • 425
  • 426
  • 427
  • 428
  • 429
  • 430
  • 431
  • 432
  • 433
  • 434
  • 435
  • 436
  • 437
  • 438
  • 439
  • 440
  • 441
  • 442
  • 443
  • 444
  • 445
  • 446
  • 447
  • 448
  • 449
  • 450
  • 451
  • 452
  • 453
  • 454
  • 455
  • 456
  • 457
  • 458
  • 459
  • 460
  • 461
  • 462
  • 463
  • 464
  • 465

Fabric OS 5.3.0 administrator guide
327
VE_Port—Functions somewhat like an E_Port, but terminates at the switch and does not propagate
fabric services or routing topology information from one edge fabric to another.
VEX_Port—A type of VE_Port that connects a Fibre Channel router to an edge fabric. From the point of
view of a switch in an edge fabric, an VEX_Port appears as a normal VE_Port. It follows the same Fibre
Channel protocol as other VE_Ports. However, the router terminates VEX_Ports rather than allowing
different fabrics to merge as would happen on a switch with regular VE_Ports.
The FCP auto discovery process enables private storage devices that accept PRLI to communicate in a
fabric.
If device probing is enabled, the embedded port PLOGIs and attempts a PRLI into the device to retrieve
information to enter into the Name Server. This enables private devices that do not FLOGI but accept PRLI
to be entered in the Name Server and receive full fabric citizenship. Private devices that accept PRLI
represent a majority of storage targets. Private hosts require the QuickLoop feature, which is not available
in Fabric OS v4.0.0 or later.
A fabric-capable device will implicitly register information with Name Server during a FLOGI. These
devices will typically register information with the Name Server before querying for a device list. The
embedded port will still PLOGI and attempt PRLI with these devices.
You can view the Name Server table in Web Tools by clicking
Name Server
in the fabric toolbar. Refer
to the
Web Tools Administrator’s Guide
for more information.
Port mirroring
Port mirroring lets you configure a switch port as an analyzer port to mirror a specific source port and
destination port traffic passing though any switch port. This is a useful way to troubleshoot without bringing
down the host and destination links to insert an inline analyzer.
Port mirroring captures traffic between two devices. It mirrors only the frames containing the SID/DID to the
mirror port. Because of the way it handles mirroring, a single mirror port can mirror multiple mirror
connections. This also means that the port cannot exceed the maximum bandwidth of the mirror port.
Attempts to mirror more traffic than available bandwidth result in the port mirror throttling the SID/DID
traffic so that traffic does not exceed the maximum available bandwidth.
Port mirroring is supported between VE_ports (VE_Port to VE_Port) with FCIP and no routing, and over VEx
_Ports and Ex_Ports. The mirror port can be any port located on the same switch as the source identifier
(SID).
Use port mirroring to detect missing frames, which might occur with zoning issues or hold timeouts, capture
protocol errors, and capture ULP traffic (SCSI/FICON). This feature cannot be used on embedded switch
traffic.
Port mirroring is only available using the FOS 5.2.x CLI and is not available through Web Tools. For a
complete list of port mirroring commands, see the Fabric OS Command Reference Manual.
In order to ensure proper failover in HA configurations, both the active and the standby control processors
(CP) must have firmware version 5.2 installed and running. If the OS on the standby CP does not support
mirroring, failing over the standby CP could cause the HA failover to fail.