Panasonic AW-RP150GJ AW-RP150 Operation Manual - Operating Instructions
Panasonic AW-RP150GJ Manual
View all Panasonic AW-RP150GJ manuals
Add to My Manuals
Save this manual to your list of manuals |
Panasonic AW-RP150GJ manual content summary:
- Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 1
Operating Instructions Remote Camera Controller Model No. AW-RP150G Before operating this product, please read the instructions carefully and save this manual for future use. Please carefully read the "Read this first!" (pages 3 to 4) of this Manual before use. GJ W1118WT0 -FJ ENGLISH DVQP1819ZA - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 2
om produkten. https://pro-av.panasonic.net/manual/en/index.html About trademarks which each of them is discussed separately. zzIn these instructions, the phrases "4K Integrated Camera" and "pan‑tilt AW‑RP150G AW-UE150WP AW-UE150KP AW-UE150WE AW-UE150KE Notation in this manual AW‑RP150 AW-UE150 2 - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 3
. No user serviceable parts inside. Refer servicing to qualified service personnel. CAUTION AW-RP150P Trade Name: Panasonic Responsible Party: Panasonic Corporation of North America Two Riverfront Plaza, Newark, NJ 07102 Support in accordance with the instruction manual, may cause harmful interference - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 4
Audio signal connecting cables If your apparatus supports AES/EBU serial digital audio signals, use cables (s), they must be attached on cable(s) following instructions in this manual. 2. Performance level The performance level of . Manufactured by: Panasonic Corporation, Osaka, Japan Importer's name - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 5
first 3 Introduction 6 Features 7 Supported remote cameras 7 Precautions for Setting the IP addresses automatically (auto IP setting 33 Manually setting the connection destination IP addresses (remote cameras) cameras 84 Messages 88 Troubleshooting 90 Appearance 91 Specifications 92 Control interface for - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 6
camera AW-UE150 ANY FAILURE OR PROBLEM OF THE PRODUCT; (5) ANY PROBLEM, CONSEQUENTIAL INCONVENIENCE, service. Upgrade software You can obtain the upgrade software from Service and Support on the following website. https://pro-av.panasonic.net/ For the upgrade procedure, refer to the instructions - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 7
assign and control the IP addresses of the remote cameras *1. *1: Supported cameras: AW-UE150 zzOne remote camera can be simultaneously controlled from up to 5 pedestal and gain for each of the R channel and B channel. Manual color adjustment is also easy. zzRapid call up operations are available for - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 8
Disposal of the unit When the unit has reached the end of its service life and is to be disposed of, ask a qualified contractor to lower may result in decreased power supply performance. When a personal computer that supports Gigabit Ethernet and a PoE+ injector are connected via a straight LAN cable - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 9
Parts and their functions Control panel Color adjustment section POWER ALARM BARS AWB ABB A/3200K B/5600K ATWVAR WHITE BAL SHUTTER ON SHUTTER SYNC SCENE ON/OFF R/B GAIN ENABLE R/B PED M.PED F1 F2 F3 F4 IRIS TELE AUTO LOW HI SPEED ZOOM WIDE ENABLE AUTO OTAF ENABLE - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 10
Parts and their functions (continued) Menu operation ENABLE button [ENABLE] Enables or disables operations with the menu operation section, user button section, and LCD panel. Hold down to turn the LCD panel off. Button indicator on : Operations with the menu operation section, user button section - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 11
. Auto iris button [AUTO] Use this to set lens iris control to "Auto (auto iris)". Button indicator on : Auto iris Button indicator off : Manual iris FOCUS/ZOOM/IRIS ENABLE button [ENABLE] Use this to enable or disable operation of the FOCUS dial (), ZOOM button () and IRIS dial (). Button - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 12
SYNC button [SHUTTER SYNC] Button indicator on : Sync shutter is set. Button indicator off : Step shutter is set. zzRefer to the operating instructions for the remote camera being connected for setting value ranges. SCENE ON/OFF button [SCENE ON/OFF] This is a button for a future expansion - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 13
can be used with the unit. The MultiMedia Card (MMC) is not supported. SDHC 4 GB to 32 GB SDXC 64 GB For the latest information not described in the Operating Instructions, refer to the following websites. https://pro-av.panasonic.net/ zzObserve the following points when using and storing the memory - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 14
for PoE+ power supply to these connectors. IP CONT connector [IP CONT] (RJ‑45) (10BASE‑T/100BASE‑TX) Connect a remote camera or computer that supports an IP connection to this connector with a LAN cable. When directly connecting a device to the unit, use a crossover cable (category 5e or better - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 15
Precautions for installation In addition to the safety precautions given in "Read this first!", also observe the following instructions. Be sure to ask your dealer to perform the installation and connection work for the unit. Connecting a power supply zzInsert the DC plug for the - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 16
Center AV-HLC100 Monitor Monitor LAN cable (Straight cable or cross cable) Max. 100 m (328 ft) External DC power supply Remote camera controller AW-RP150 zzUse a category 5e cable for the LAN cable. zzIt is possible to have a mixture of remote cameras connected via serial connections and - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 17
cross cable) Max. 100 m (328 ft) PoE+ supported switching hub or PoE+ injector Remote camera controller AW‑RP150 Remote camera controller AW‑RP150 Remote camera controller AW‑RP150 Remote camera controller AW‑RP150 Remote camera controller AW‑RP150 External DC power supply External DC power - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 18
1 Monitor Serial control signals LAN cables (Straight cable) Max. 1000 m (3280 ft) Monitor 2 Monitor External DC power supply Remote camera controller AW‑RP150 zzUse a straight cable (category 5e cable) for the LAN cable. zzWhen serial connections are used, up to five remote cameras can be - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 19
(continued) Example of connection for the function for cropping 4K images to HD images AW-UE150 AW-UE150 3G SDI OUT External DC power supply MONI OUT Monitor LAN cables (Straight cable a category 5e cable for the LAN cable. External DC Remote camera controller power supply AW‑RP150 19 - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 20
button [ENABLE] indicator is on, turn the FOCUS dial to adjust the lens focus. When the one‑touch auto focus button is pressed during manual focusing, the mode switches to auto focusing mode temporarily, and the subject is brought into focus automatically. zzOTAF (one‑touch auto focus) is enabled - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 21
the [SYSTEM] button to light it. 2. Touch "CAMERA" at the top of the LCD panel to display the "CAM POWER" item. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 1 / 1 5 RP IP SET 1 CAM POWER AUTO POWER CAM LOCK NON ON UNLOCK 11 Turning on the - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 22
1. Press the [SYSTEM] button. 2. Touch "CAMERA" at the top of the LCD panel to display the "CAM POWER" item. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 1 / 1 5 RP IP SET 1 CAM POWER AUTO POWER CAM LOCK NON ON UNLOCK 11 Turning off the - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 23
Selecting a camera group This unit allows you to register up to 200 remote cameras as control targets by configuring the connection settings for each of the camera numbers CAM1 to CAM200. To select a remote camera to control from these cameras, you need to select the camera group to which it - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 24
Lighting state of the indicator Remote camera state Off Not connected On (amber) Camera standby On (green) zzCamera connected zzMultiple AW-RP150s connected to the camera zzCamera selection buttons Lighting state of the indicator Off Unselected Remote camera state On (green) G_TALLY - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 25
selection button lights, you can control the remote camera from the unit. 1 CAM112 :AW-UE150 TALLY : 1/2 CAM I R I S : CLOSE 2 112 ZOOM : 0 0 ZOOM ENABLE GAIN SHTER SPEED SCENE COLOR TMP 4 0dB - SCENE1 - CAM112 :AW-UE150 TALLY : CAM I R I S : CLOSE 7 112 ZOOM : WIDE FOCUS : - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 26
connection with the camera is via LAN, up to 10 characters of the name set on the camera can be displayed. Refer to the operating instructions for the camera for camera name settings. 2 Camera number, lens position Displays the currently selected camera number, and the status of IRIS, ZOOM, and - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 27
on the LCD panel (A) of the unit. zzTouch panel operations can be performed within the touch operation areas B. A C BARS CAM01 : AW-UE150 1 / 2 1 2 3 4 5 SCENE SHUTTER PED CHROMA GAIN ABB B 6 7 8 9 WHITE BALANCE GAMMA BLACK GAMMA DRS 10 KNEE 1 SCENE SCENE1 ATWVAR 11 SCENE - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 28
display off and status screen is displayed. For details, refer to "Menu group" (page 39). BARS I ABB ATWVAR J SCENE ON/OFF CAM01 : AW-UE150 1 / 2 1 2 3 4 5 SCENE SHUTTER PED CHROMA GAIN 6 7 8 9 WHITE BALANCE GAMMA BLACK GAMMA DRS 10 KNEE 1 SCENE SCENE1 11 ENABLE D PAINT USER - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 29
the page switching buttons (up and down) (N). BARS ABB ATWVAR SCENE ON/OFF CAM01 : AW-UE150 1 / 2 1 2 3 4 5 SCENE SHUTTER PED CHROMA GAIN 6 7 4 SYSTEM USER 5 PICTURE USER 6 L BARS ABB ATWVAR SCENE ON/OFF CAM01 : AW-UE150 1 / 2 1 2 3 4 5 SCENE SHUTTER PED CHROMA GAIN 6 7 - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 30
Setting the IP address of the unit 1. Press the [SYSTEM] button. 2. Touch "RP IP SET" to display the "IP" item. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 1 / 2 5 RP IP SET 1 IP 192 168 2 SUBNET 255 255 3 GATEWAY 192 168 4 NW SET STATIC - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 31
camera group. 1. Press the [SYSTEM] button. 2. Touch "RP IP SET" to display the "PORT C1" to "PORT C10" items. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 2 / 2 5 RP IP SET 6 PORT C1 61000 PORT C2 61002 PORT C3 61004 PORT C4 61006 7 PORT C5 - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 32
The IP address for the unit to identify the connection target (remote camera) is referred to as the "connection destination IP address" in this manual. One connection destination IP address is allocated for each of the remote cameras connected to the unit, from camera number CAM1 to CAM200, for - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 33
1. Set the connection types for camera numbers CAM1 to CAM200. Display the menu items with [SYSTEM] button > [CONNECT SETTING]. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 1 / 11 5 RP IP SET 1 CAM SEL CNNCT MD DATA SAVE DATA LOAD 1 Serial NO? NO - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 34
message is displayed when IP address setting fails. The cause of the problem is likely to be a network malfunction. Check the connection status of SET" item to "RENEW", then press the F1 dial. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 1 / 1 5 RP IP SET - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 35
subnet. 2. Select the "AUTO IP SET" SYSTEM menu, turn the F1 dial to display "RENEW", then press the F1 dial. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 1 / 1 5 RP IP SET 1 AUTO SET NON NEW 0 TOTAL 0 EXEC NON 11 The number of devices currently - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 36
ERR" message is displayed when IP address setting fails. The cause of the problem is likely to be a network malfunction. Check the connection status of the Connection destination IP address set on the unit ([SYSTEM] button > [MANUAL IP SET]) CAM4 : 192.168.0.13 Leaving the IP addresses of the - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 37
dial to display "KEEP", then press the F1 dial. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 1 / 1 5 RP IP message is displayed when IP address setting fails. The cause of the problem is likely to be a network malfunction. Check the connection status of - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 38
IP SET" SYSTEM menu, turn the F1 dial to display the camera number whose settings you want to change. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 1 / 1 5 RP IP SET 1 CAM SEL 1 2 CAM IP 192 168 3 PORT 80 0 10 UPLOAD NO? 11 2. Set the IP - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 39
SEL GPO CAM.G GPI PMEM GPI PMEM.G CAMERA CONNECT SETTING MANUAL IP SET AUTO IP SET RP IP SET TRACKING PMEM LIST PMEM page 66) ⇒ "GPI PMEM.G" (page 67) ⇒ "CAMERA" (page 69) ⇒ "CONNECT SETTING" (page 70) ⇒ "MANUAL IP SET" (page 71) ⇒ "AUTO IP SET" (page 72) ⇒ "RP IP SET" (page 73) ⇒ "TRACKING - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 40
" (page 48) ⇒ "DNR" (page 49) ⇒ "BRIGHTNESS" (page 50) SCENE zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 / 2 1 2 3 4 5 SCENE SHUTTER PED CHROMA GAIN 6 7 8 9 WHITE BALANCE GAMMA BLACK GAMMA DRS 10 KNEE 1 SCENE SCENE1 11 Item SCENE - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 41
the camera. Set the maximum shutter level when ELC is operating. PED zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 / 2 1 2 3 4 5 SCENE SHUTTER PED CHROMA GAIN 6 7 8 9 WHITE BALANCE GAMMA BLACK GAMMA DRS 10 KNEE 1 R PED G PED B PED M.PED - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 42
adjustments to the hue of the colors in the images. GAIN zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 / 2 1 2 3 4 5 SCENE SHUTTER PED CHROMA GAIN 6 7 8 9 WHITE BALANCE GAMMA BLACK GAMMA DRS 10 KNEE 1 SUPER GAIN OFF GAIN 0dB AGC MAX 18dB - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 43
Menu (continued) WHITE BALANCE zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 / 2 1 2 3 4 5 SCENE SHUTTER PED CHROMA GAIN 6 7 8 9 WHITE BALANCE GAMMA BLACK GAMMA DRS 10 KNEE 1 MODE COLOR TMP R GAIN B GAIN AWB A - 0 0 2 OFFSET OFF 3 - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 44
[MODE], you can adjust the knee point. BLACK GAMMA zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 / 2 1 2 3 4 5 SCENE SHUTTER PED CHROMA GAIN 6 7 8 9 WHITE BALANCE GAMMA BLACK GAMMA DRS 10 KNEE 1 B.GAMMA RANGE 0 1 11 Item B.GAMMA RANGE - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 45
when video with high light/dark contrast is displayed. KNEE zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 / 2 1 2 3 4 5 SCENE SHUTTER PED CHROMA GAIN 6 7 8 9 WHITE BALANCE GAMMA BLACK GAMMA DRS 10 KNEE 1 MODE A.KNEE RES POINT SLOPE AUTO - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 46
setting values will vary depending on the connected camera. CAM01 : AW-UE150 11 WHITE CLIP 16 DNR 1 CLIP ON 12 13 Setting details DTL zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 2 / 2 11 12 13 14 15 WHITE CLIP DTL DC DTL MATRIX COLOR - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 47
setting values will vary depending on the connected camera. CAM01 : AW-UE150 2 / 2 11 12 13 14 15 WHITE CLIP 4K to HD. MATRIX zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 11 12 13 WHITE CLIP DTL DC DTL 16 17 DNR BRIGHT NESS 1 TYPE NORMAL - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 48
3 SAT B_Mg PHS B_Mg 0 0 SAT Mg 0 PHS Mg 0 12 4 SAT Mg_R PHS Mg_R SAT Mg_R_R PHS Mg_R_R 0 0 0 0 5 SAT R PHS R SAT R_R_Yl PHS R_R_Yl 0 0 0 0 CAM01 : AW-UE150 2 / 2 11 12 13 14 15 WHITE CLIP DTL DC DTL MATRIX COLOR CORRE 16 17 DNR BRIGHT NESS 6 SAT R_Yl PHS R_Yl SAT - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 49
cyan and blue. Adjust the saturation of blue. Adjust the hue of blue. DNR zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 11 12 13 WHITE CLIP DTL DC DTL 16 17 DNR BRIGHT NESS 1 DNR LOW 2 / 2 14 15 MATRIX COLOR CORRE 11 DNR Item Setting - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 50
Menu (continued) BRIGHTNESS zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 2 / 2 11 12 13 14 15 WHITE CLIP DTL DC DTL MATRIX COLOR CORRE 16 17 DNR BRIGHT NESS 1 PCTR LV FRM MIX DAY / NIGHT 0 - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 51
) ⇒ "HOUSING INFO" (page 55) ⇒ "CROP" (page 56) USER ASSIGN zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 USER ASSIGN 6 CROP 2 CAMERA INFO 3 PTZ INFO1 4 PTZ INFO2 1 / 1 5 HOUSING INFO 1 SHUOSOETRI1NG USNEDR12 2 USER5 ND4 USER6 D.EXT 3 USER9 CROP - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 52
Menu (continued) CAMERA INFO zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 USER ASSIGN 6 CROP 2 CAMERA INFO 3 PTZ INFO1 4 PTZ INFO2 1 ND ND1 OPT SHOOTING OFF NORMAL 2 D.ZOOM OFF D.ZM MAX ×10 D.EXT OFF 3 I.S. OFF 4 AN. - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 53
Menu (continued) PTZ INFO1 zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 USER ASSIGN 6 CROP 2 CAMERA INFO 3 PTZ INFO1 4 PTZ INFO2 1 / 1 5 HOUSING INFO 1 SPD WTH Z ON Z MIN SPD OFF FREEZE OFF 2 LMOTFFUP LMTODFOFWN LMTOFLFEFT LMTORFIFGHT 3 P / T - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 54
Menu (continued) PTZ INFO2 zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 USER ASSIGN 6 CROP 2 CAMERA INFO 3 PTZ INFO1 4 PTZ INFO2 1 / 1 5 HOUSING INFO 1 CAM SEL CAM1 2 NPOARNMDAIRL NTIOLRTMDAIRL ZNOOORMMDAILR FONCOURSMADLIR 3 IRIS DIR NORMAL 11 - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 55
Menu (continued) HOUSING INFO zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 USER ASSIGN 6 CROP 2 CAMERA INFO 3 PTZ INFO1 4 PTZ INFO2 1 FAN HIGH HEATER DEFRSTER - - 2 WASHER - 1 / 1 5 HOUSING INFO WIPER - 11 Item FAN HEATER DEFRSTER WIPER WASHER - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 56
Menu (continued) CROP zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 USER ASSIGN 6 CROP 2 CAMERA INFO 3 PTZ INFO1 4 PTZ INFO2 1 SW OFF ADJUST YL H POS 128 2 OYULT YMLA+RGK+MERG 1 / 1 5 HOUSING INFO V POS 120 11 - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 57
(page 65) ⇒ "GPI PMEM" (page 66) ⇒ "GPI PMEM.G" (page 67) CAMERA MENU OP zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 CAMERA MENU OP 6 GPI TALLY 1 MENU OFF 2 RP SETTING 7 GPIO CAM SEL 3 FILES 8 GPO CAM.G 4 RP INIT 9 GPI PMEM CURSOR EXECUTE (turn - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 58
Menu (continued) RP SETTING zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 CAMERA MENU OP 6 GPI TALLY 2 RP SETTING 7 GPIO CAM SEL 3 FILES 8 GPO CAM.G 4 RP INIT 9 GPI PMEM 1 / 1 5 RP VERSION 10 GPI PMEM.G 1 A.KNOB1 A.KNOB2 A. - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 59
Menu (continued) Item LED BRI BUZZER*1 DATA SAVE DATA LOAD CARD FRMT Setting value 1 ⁞ 15 OFF ON NO? YES? NO? YES? YES(+NW)? NO? YES? Setting details Set the brightness of the panel buttons. Enable (on) or disable (off) the buzzer (beep). Save the unit's setting information. zzAfter starting this - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 60
Menu (continued) FILES zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 CAMERA MENU OP 6 GPI TALLY 2 RP SETTING 7 GPIO CAM SEL 1 MODE LOAD 2 SELECT CAMERA ALL 3 FILE - 4 EXECUTE NO? 3 FILES 8 GPO CAM.G 5 4 RP INIT 9 GPI - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 61
unit, excluding network settings, to the factory default conditions. RP VERSION zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 CAMERA MENU OP 6 GPI TALLY 2 RP SETTING 7 GPIO CAM SEL 3 FILES 8 GPO CAM.G 1 SYSTEM VERSION x.xx - xx - x.xx SOFT VERSION x.xx - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 62
Menu (continued) GPI TALLY zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 CAMERA MENU OP 6 GPI TALLY 2 RP SETTING 7 GPIO CAM SEL 3 FILES 8 GPO CAM.G 4 RP INIT 9 GPI PMEM 1 / 1 5 RP VERSION 10 GPI PMEM.G 1 TALLY OUT - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 63
IN8 CAM8 3 IN9 CAM9 IN10 CAM10 12 4 OUT1 CAM1 OUT2 CAM2 OUT3 CAM3 OUT4 CAM4 5 OUT5 CAM5 OUT6 CAM6 OUT7 CAM7 OUT8 CAM8 CAM01 : AW-UE150 1 CAMERA MENU OP 6 GPI TALLY 6 OUT9 CAM9 2 RP SETTING 7 GPIO CAM SEL 3 FILES 8 GPO CAM.G OUT10 CAM10 4 RP INIT 9 GPI PMEM 1 / 1 5 RP VERSION - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 64
Menu (continued) IN4*1 Item IN5*1 IN6*1 IN7*1 IN8*1 IN9*1 IN10*1 OUT1*1 OUT2*1 OUT3*1 OUT4*1 OUT5*1 OUT6*1 OUT7*1 OUT8*1 Setting value CAM1 ⁞ CAM4 ⁞ CAM200 CAM1 ⁞ CAM5 ⁞ CAM200 CAM1 ⁞ CAM6 ⁞ CAM200 CAM1 ⁞ CAM7 ⁞ CAM200 CAM1 ⁞ CAM8 ⁞ CAM200 CAM1 ⁞ CAM9 ⁞ CAM200 CAM1 ⁞ CAM10 ⁞ CAM200 - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 65
the applicable camera number in the currently selected camera group. GPO CAM.G zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 CAMERA MENU OP 6 GPI TALLY 2 RP SETTING 7 GPIO CAM SEL 3 FILES 8 GPO CAM.G 4 RP INIT 9 GPI PMEM 1 / 1 5 RP VERSION 10 GPI PMEM - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 66
Menu (continued) GPI PMEM zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 CAMERA MENU OP 6 GPI TALLY 2 RP SETTING 7 GPIO CAM SEL 3 FILES 8 GPO CAM.G 4 RP INIT 9 GPI PMEM 1 / 1 5 RP VERSION 10 GPI PMEM.G 1 IN1 PMEM1 - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 67
SEL6 PM PMEM1 5 SEL7 CAM CAM7 SEL7 PM PMEM1 SEL8 CAM CAM8 SEL8 PM PMEM1 CAM01 : AW-UE150 1 CAMERA MENU OP 6 GPI TALLY 2 RP SETTING 7 GPIO CAM SEL 3 FILES 8 there is input to PRESET_MEM_GROUP_IN1 to 4, preset playback instructions are performed according to the subsequent settings SEL1 to - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 68
Menu (continued) Item SEL3 CAM*1 SEL3 PM*1 SEL4 CAM*1 SEL4 PM*1 SEL5 CAM*1 SEL5 PM*1 SEL6 CAM*1 SEL6 PM*1 SEL7 CAM*1 SEL7 PM*1 SEL8 CAM*1 SEL8 PM*1 SEL9 CAM*1 SEL9 PM*1 SEL10 CAM*1 SEL10 PM*1 Setting value CAM1 ⁞ CAM3 ⁞ CAM200 PMEM1 ⁞ PMEM100 CAM1 ⁞ CAM4 ⁞ CAM200 PMEM1 ⁞ PMEM100 CAM1 ⁞ CAM5 ⁞ - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 69
setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 1 CAM POWER AUTO POWER Off (standby) instructions in regard to remote cameras set in this unit. ALL ON: Execute power On instructions in regard to - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 70
CAM7 NON CAM8 NON 1 11 4 CAM9 NON CAM10 NON CAM11 NON CAM12 NON 5 CAM13 NON CAM14 NON CAM15 NON CAM16 NON CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 46 CAM177 NON 47 CAM181 NON 48 CAM185 NON 49 CAM189 NON 50 CAM193 NON CAM178 NON - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 71
IP SET zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 1 / 1 5 RP IP SET 1 CAM SEL 1 2 CAM IP 192 168 3 PORT 80 0 10 UPLOAD NO? 11 ___ indicates factory default settings. - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 72
Menu (continued) AUTO IP SET zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 1 / 1 5 RP IP SET 1 AUTO SET NON NEW 0 TOTAL 0 EXEC NON 11 Item AUTO SET NEW TOTAL EXEC Setting value - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 73
1 5 RP IP SET 1 IP 192 168 2 SUBNET 255 255 3 GATEWAY 192 168 4 NW SET STATIC 5 0 9 255 0 0 1 12 UPLOAD NO? CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 1 / 1 5 RP IP SET 6 PORT C1 61000 PORT C2 61002 PORT C3 61004 PORT C4 61006 - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 74
Menu (continued) TRACKING zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 1 / 1 5 RP IP SET 1 TR CONT NON 2 TR IP 192 168 3 PORT 1337 0 210 UPLOAD NO? 11 ___ indicates factory - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 75
/tilt positions zzZoom positions zzFocus positions zzLens iris settings (manual iris only) zzWhite balance settings zzGain Notes zzThe number of depending on the remote camera. For details, check the Operating Instructions for the corresponding model. zzThe starting positions for the preset memory - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 76
6 PRE6 10 PRE10 14 PRE14 18 PRE18 3 PRE3 7 PRE7 11 PRE11 15 PRE15 19 PRE19 4 PRE4 8 PRE8 12 PRE12 15 16 PRE16 20 PRE20 CAM01 : AW-UE150 1 / 1 1 2 3 4 5 PMEM PMEM PMEM PMEM LIST DIRECT STORE DEL TMEM 6 SETTING STORE : Push F1 + PMEM No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 77
Menu (continued) PMEM DIRECT zzYou can directly instruct to execute by entering the preset number. CAM01 : AW-UE150 1 PMEM LIST 6 SETTING 2 PMEM DIRECT 3 PMEM STORE 4 PMEM DEL 1 / 1 5 TMEM 1 RCL SP MD CAMERA SPEED MD STEP SPEED 20 PMEM 1 1 2 3 4 5 6 11 7 8 9 CLEAR 0 EXEC - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 78
Menu (continued) PMEM STORE zzYou can register the preset memory by entering the preset number. CAM01 : AW-UE150 1 PMEM LIST 6 SETTING 2 PMEM DIRECT 3 PMEM STORE 4 PMEM DEL 1 / 1 5 TMEM 1 RCL SP MD CAMERA SPEED MD STEP SPEED 20 PMEM 1 1 2 3 4 5 6 11 7 8 9 CLEAR 0 EXEC Item - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 79
Menu (continued) PMEM DEL zzYou can delete the preset memory. CAM01 : AW-UE150 1 PMEM LIST 6 SETTING 2 PMEM DIRECT 3 PMEM STORE 4 PMEM DEL 1 / 1 5 TMEM 1 MODE RANGE START 1 END 1 PMEM 1 2 3 4 5 6 11 7 8 9 CLEAR 0 EXEC Item MODE START END PMEM 0 ⁞ 9 CLEAR - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 80
Menu (continued) TMEM zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 PMEM LIST 6 SETTING 2 PMEM DIRECT 3 PMEM STORE 4 PMEM DEL 1 / 1 5 TMEM 1 MODE from more than one AW-RP150. If tracing memory operations are performed on the same remote camera from - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 81
Menu (continued) SETTING zzMake basic settings for preset memory and tracing memory. CAM01 : AW-UE150 1 PMEM LIST 6 SETTING 2 PMEM DIRECT 3 PMEM STORE 4 PMEM DEL 1 / 1 5 TMEM 1 SCOPE RCL SP MD A CAMERA HOME NO? 2 SPD UNIT SPEED TBL SPEED STEP FAST 1 3 D- - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 82
Menu (continued) Item PM G.CAL*1 Setting value GROUP1 ⁞ GROUP4 Setting details Execute the setting content for [GPI IN SEL] set with the [MAINTENANCE] button > [GPI PMEM.G] menu. Select the target group and press the F1 dial to execute. GROUP1: IN1 for GPI IN SEL GROUP2: IN2 for GPI IN SEL GROUP3 - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 83
how to install Setup Software. You can obtain the software from the Service and Support page of the following website. https://pro-av.panasonic.net/ 1. Download the Setup Software zip file from the Service and Support page of the website. 2. Double-click the downloaded zip file to decompress - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 84
Setup Software (continued) The screens of Windows 7 are used in the explanations in this manual. If you are using an operating system other than Windows 7, some of the items displayed on the screens may differ. Settings for connecting with the - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 85
Setup Software (continued) 11 SAVE button The set data is saved. Save the data file saved here under \PRIVATE\MEIGROUP\PAVCN\SBG\SYSCAM\RP150\DATA. When loaded with "DATA LOAD" in the [SYSTEM] button > [CONNECT SETTING] menu of this unit, the results are updated in the main unit. Note zzBe aware - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 86
Setup Software (continued) Displaying the [Preset Name] tab You can set a name of up to 8 characters for a preset number. You can edit the data saved with the [PMEM/TMEM] button > [SETTING] > [PM NM SV]. By saving the data after editing and "LOAD" to the main unit, it can be displayed in the PMEM - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 87
Setup Software (continued) Displaying the [User Auth.] tab Perform user authentication settings for the connection destination remote camera. Cameras can be set individually or all at once. These settings are set based on the data saved with "DATA SAVE" with the [SYSTEM] button > [CONNECT SETTING] - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 88
memory card has been correctly inserted. ⇒ C heck that the memory card is supported by the unit. ⇒ C heck that the memory card has been formatted. ⇒ memory card has been correctly inserted. ⇒ C heck that the memory card is supported by the unit. ⇒ C heck if the write protect switch on the card - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 89
Messages (continued) Setup software Indication Unavailable network setting. Entered information is incorrect. Enter again. Complete the "New User Name" field. Complete the "New Password" field. Complete the "Retype New Password" field. Password entered in the "Retype New Password" field is - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 90
Troubleshooting Symptom Cause and Measure Cannot turn the power of the unit on. with the actual installation state (mounted right side up or upside down). Refer to the Operating Instructions for the remote camera. zzIs the movement direction set properly on the unit? The remote camera moves - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 91
Appearance 317 (12-15/32) RS-442 LAN GPIO 2 TALLY/GPIO 1 THRU OUT ACTIVE IN 5 4 3 2 1 LINK ACT 12V IN 3G SDI SERIAL CONT IP CONT SIGNAL GND POWER ON POWER ALARM BARS AWB ABB A/3200K B/5600K ATWVAR WHITE BAL SHUTTER ON SHUTTER SYNC SCENE ON/OFF R/B GAIN ENABLE R/B PED M. - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 92
(including the accessories) represent the following: DC Input/output connectors DC 12 V IN (XLR 4‑pin) 3G SDI IN / 3G SDI ACTIVE THRU OUT: SMPTE292/75 Ω Supported formats: 1080/59.94p*, 1080/59.94i, 1080/23.98p, 1080/23.98PsF, 1080/50p*, 1080/50i, 1080/25p, 1080/25PsF *: Only Level A is - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 93
output (Status operation) Example of GPI OUT connection Ensure that the conditions given below are satisfied. Withstand voltage: Max. 24 V DC Current: Max. 50 mA AW‑RP150 (Max. voltage 24 V) GPI OUT (Max. current 50 mA) GND Example of TALLY IN and GPI IN connections Provide contact inputs - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 94
Control interface for external devices (continued) You can allocate the "GPIO" settings as follows in [MAINTENANCE] > [RP SETTING] > [GPIO MD] in the menus. GPIO MODE: MODE1 DSUB1 Pin number Signal name 1 R_TALLY_IN_1 *1 14 R_TALLY_IN_2 *1 2 R_TALLY_IN_3 *1 15 R_TALLY_IN_4 *1 3 - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 95
Control interface for external devices (continued) 2. GPIO 2 (JST: JBY‑25S‑1A3F(LF)(SN)) 13 1 Pin number Signal name Description of signal 1 DSUB2_GPI_1 14 DSUB2_GPI_2 25 14 2 DSUB2_GPI_3 It is possible to allocate "GPI" 15 DSUB2_GPI_4 settings in the [MAINTENANCE] > 3 16 - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 96
withstand: Max. 24 V DC Current: Max. 50 mA 6. IP CONT (RJ-45) Complies with 10BASE-T/100BASE-TX. Allowing connection to a network device that supports the PoE+ standard (IEEE802.3at compliant). 7. 12V IN (DC 12 V) Hirose Electric: HA16RA-4P (77) Accepts DC 12V inputs from an external power - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 97
SDI IN 92, 96 3G SDI OUT 19 A Auto IP setting 33 AV-HLC100 16 AW-UE150 7, 16, 17, 18, 19 C Camera selection section 10 Color adjustment section 12 mask 30 SYSTEM 69 AUTO IP SET 72 CAMERA 69 CONNECT SETTING 70 MANUAL IP SET 71 RP IP SET 73 TRACKING 74 T TALLY/GPIO 1 14, 92, - Panasonic AW-RP150GJ | AW-RP150 Operation Manual - Operating Instructions - Page 98
Web Site: http://www.panasonic.com © Panasonic Corporation 2018
Operating Instructions
Remote Camera Controller
Model No.
AW-RP150G
DVQP1819ZA
W1118WT0 -FJ
ENGLISH
GJ
Before operating this product, please read the instructions carefully and save this manual for future use.
Please carefully read the “Read this first!” (pages 3 to 4) of this Manual before use.