Panasonic AW-RP150GJ AW-RP150 Operation Manual - Operating Instructions - Page 31

Port C1, Port C2, Port C4, Port C3, Port C5, Port C6, Port C8, Port C7, Port C9, Port C10, Mac

Page 31 highlights

Network settings of the unit (continued) Setting the default gateway 1. Press the [SYSTEM] button. 2. Touch "RP IP SET" to display the "GATEWAY" item. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 1 / 2 5 RP IP SET 1 IP 192 168 2 SUBNET 255 255 3 GATEWAY 192 168 4 NW SET STATIC 5 0 9 255 0 0 1 12 UPLOAD NO? zzThis is set to "192.168.0.1" by default. 3. Press the cursor movement buttons to select "GATEWAY". 4. Use the menu operation dials to set the default gateway of the unit. Enter this in 4 blocks of numerals. If "UPLOAD" in the fifth row is not executed, the changes are not updated. Note zzIn order for the setting to take effect, the unit must be restarted. Turn off the unit's power, and then turn it back on. Settable addresses 1 IP 192 168 0 9 Block 1 Block 2 Block 3 Block 4 zzFor the IP address, you can set values within the following ranges. Block 1: 1 to 223 Block 2: 0 to 255 Block 3: 0 to 255 Block 4: 1 to 254 However, "127.0.0.1" cannot be set even though it is within the above ranges. zzFor the subnet mask, you can set values within the following ranges. Block 1: 0 to 255 Block 2: 0 to 255 Block 3: 0 to 255 Block 4: 0 to 255 However, "0.0.0.0" and "127.0.0.1" cannot be set even though they are within the above ranges. Displaying the MAC address 1. Press the [SYSTEM] button. 2. Touch "RP IP SET" to display the "MAC ADDRESS" item. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 2 / 2 5 RP IP SET 6 PORT C1 61000 PORT C2 61002 PORT C3 61004 PORT C4 61006 7 PORT C5 61008 PORT C6 61010 PORT C7 61012 PORT C8 61014 8 PORT C9 61016 PORT C10 61018 22 9 xx -MxAxC- xAxD-DxRxE-SxSx - xx zzThe MAC address can only be displayed. It cannot be changed. Setting the reception port numbers Set the port numbers for receiving camera information update notifications from remote cameras. Set this when connecting remote cameras via a router. zzSet 10 port numbers because update notifications are received from the remote cameras in the selected camera group. 1. Press the [SYSTEM] button. 2. Touch "RP IP SET" to display the "PORT C1" to "PORT C10" items. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 2 / 2 5 RP IP SET 6 PORT C1 61000 PORT C2 61002 PORT C3 61004 PORT C4 61006 7 PORT C5 61008 PORT C6 61010 PORT C7 61012 PORT C8 61014 8 PORT C9 61016 PORT C10 61018 22 9 xx -MxAxC- xAxD-DxRxE-SxSx - xx 3. Use the menu operation dials to set the reception port number for each camera number. Input range : 61000 to 65535 zz"Unavailable Subnetmask setting" is displayed if a port number for a duplicated reception port is entered. 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98

31
Setting the default gateway
Press the [SYSTEM] button.
Touch “RP IP SET” to display the “GATEWAY” item.
CAMERA
CAM01 :
AW-UE150
1 / 2
192
IP
168
0
9
255
SUBNET
255
255
0
192
168
0
1
GATEWAY
STATIC
NW SET
NO?
UPLOAD
12
1
2
3
4
5
6
TRACKING
CONNECT
SETTING
MANUAL
IP SET
AUTO
IP SET
RP
IP SET
1
2
3
4
5
z
This is set to “192.168.0.1” by default.
Press the cursor movement buttons to select
“GATEWAY”.
Use the menu operation dials to set the default gateway
of the unit.
Enter this in 4 blocks of numerals.
If “UPLOAD” in the fifth row is not executed, the changes are not
updated.
z
In order for the setting to take effect, the unit must be
restarted. Turn off the unit’s power, and then turn it back on.
Note
Settable addresses
192
IP
168
0
9
1
Block 1
Block 2
Block 3
Block 4
z
For the IP address, you can set values within the following ranges.
Block 1: 1 to 223
Block 2: 0 to 255
Block 3: 0 to 255
Block 4: 1 to 254
However, “127.0.0.1” cannot be set even though it is within the above
ranges.
z
For the subnet mask, you can set values within the following ranges.
Block 1: 0 to 255
Block 2: 0 to 255
Block 3: 0 to 255
Block 4: 0 to 255
However, “0.0.0.0” and “127.0.0.1” cannot be set even though they
are within the above ranges.
Displaying the MAC address
Press the [SYSTEM] button.
Touch “RP IP SET” to display the “MAC ADDRESS”
item.
61000
61002
61006
61004
61008
61010
61014
61012
61016
61018
PORT C1
PORT C2
PORT C4
PORT C3
CAM01 :
AW-UE150
6
PORT C5
PORT C6
PORT C8
PORT C7
7
PORT C9
PORT C10
8
xx - xx - xx - xx - xx - xx
MAC ADDRESS
9
22
1
2
3
4
5
6
CAMERA
2 / 2
TRACKING
CONNECT
SETTING
MANUAL
IP SET
AUTO
IP SET
RP
IP SET
z
The MAC address can only be displayed. It cannot be changed.
Setting the reception port numbers
Set the port numbers for receiving camera information update
notifications from remote cameras.
Set this when connecting remote cameras via a router.
z
Set 10 port numbers because update notifications are received from
the remote cameras in the selected camera group.
Press the [SYSTEM] button.
Touch “RP IP SET” to display the “PORT C1” to “PORT
C10” items.
61000
61002
61006
61004
61008
61010
61014
61012
61016
61018
PORT C1
PORT C2
PORT C4
PORT C3
CAM01 :
AW-UE150
6
PORT C5
PORT C6
PORT C8
PORT C7
7
PORT C9
PORT C10
8
xx - xx - xx - xx - xx - xx
MAC ADDRESS
9
22
1
2
3
4
5
6
CAMERA
2 / 2
TRACKING
CONNECT
SETTING
MANUAL
IP SET
AUTO
IP SET
RP
IP SET
Use the menu operation dials to set the reception port
number for each camera number.
Input range
:
61000 to 65535
z
“Unavailable Subnetmask setting” is displayed if a port number for
a duplicated reception port is entered.
Network settings of the unit
(continued)