Panasonic AW-RP150GJ AW-RP150 Operation Manual - Operating Instructions - Page 96
G Sdi Active Thru Out, Serial Cont 1 To 5 Rj-45, Ip Cont Rj-45, In Dc 12 V, 3g Sdi
View all Panasonic AW-RP150GJ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 96 highlights
Control interface for external devices (continued) 3. 3G SDI ACTIVE THRU OUT BNC 75 Ω The HD/SDI signals input through SDI IN are output as they are. zzSignals are not output unless the power of this unit is on. 4. 3G SDI IN BNC 75 Ω When the [PICTURE] button is lit, the input video is displayed on the LCD panel. 5. SERIAL CONT 1 to 5 (RJ-45) Connect remote cameras with support for a serial connection to these connectors using LAN cables. Connect them with straight cables (category 5e or better shielded cable). Pin number 1 2 3 4 5 6 7 8 Signal name GND TALLY TXD - RXD - RXD+ TXD+ NC NC Description of signal Frame ground Tally output (open collector) Send data (-) Receive data (-) Receive data (+) Send data (+) Not used Not used zzTALLY (pin number: 2) specifications Voltage withstand: Max. 24 V DC Current: Max. 50 mA 6. IP CONT (RJ-45) Complies with 10BASE-T/100BASE-TX. Allowing connection to a network device that supports the PoE+ standard (IEEE802.3at compliant). 7. 12V IN (DC 12 V) Hirose Electric: HA16RA-4P (77) Accepts DC 12V inputs from an external power supply. Input voltage range: 10.8 V to 13.2 V Pin No. Function 1 1 2 2 3 4 3 GND NC NC 4 +12V 96