Panasonic AW-RP150GJ AW-RP150 Operation Manual - Operating Instructions - Page 96

G Sdi Active Thru Out, Serial Cont 1 To 5 Rj-45, Ip Cont Rj-45, In Dc 12 V, 3g Sdi

Page 96 highlights

Control interface for external devices (continued) 3. 3G SDI ACTIVE THRU OUT BNC 75 Ω The HD/SDI signals input through SDI IN are output as they are. zzSignals are not output unless the power of this unit is on. 4. 3G SDI IN BNC 75 Ω When the [PICTURE] button is lit, the input video is displayed on the LCD panel. 5. SERIAL CONT 1 to 5 (RJ-45) Connect remote cameras with support for a serial connection to these connectors using LAN cables. Connect them with straight cables (category 5e or better shielded cable). Pin number 1 2 3 4 5 6 7 8 Signal name GND TALLY TXD - RXD - RXD+ TXD+ NC NC Description of signal Frame ground Tally output (open collector) Send data (-) Receive data (-) Receive data (+) Send data (+) Not used Not used zzTALLY (pin number: 2) specifications Voltage withstand: Max. 24 V DC Current: Max. 50 mA 6. IP CONT (RJ-45) Complies with 10BASE-T/100BASE-TX. Allowing connection to a network device that supports the PoE+ standard (IEEE802.3at compliant). 7. 12V IN (DC 12 V) Hirose Electric: HA16RA-4P (77) Accepts DC 12V inputs from an external power supply. Input voltage range: 10.8 V to 13.2 V Pin No. Function 1 1 2 2 3 4 3 GND NC NC 4 +12V 96

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98

96
Control interface for external devices
(continued)
3G SDI ACTIVE THRU OUT
BNC 75 Ω
The HD/SDI signals input through SDI IN are output as they are.
z
Signals are not output unless the power of this unit is on.
3G SDI IN
BNC 75 Ω
When the [PICTURE] button is lit, the input video is displayed on the
LCD panel.
SERIAL CONT 1 to 5 (RJ-45)
Connect remote cameras with support for a serial connection to these
connectors using LAN cables.
Connect them with straight cables (category 5e or better shielded cable).
Pin
number
Signal name
Description of signal
1
GND
Frame ground
2
TALLY
Tally output (open collector)
3
TXD –
Send data (–)
4
RXD –
Receive data (–)
5
RXD+
Receive data (+)
6
TXD+
Send data (+)
7
NC
Not used
8
NC
Not used
z
TALLY (pin number: 2) specifications
Voltage withstand: Max. 24 V DC
Current: Max. 50 mA
IP CONT (RJ-45)
Complies with 10BASE‑T/100BASE‑TX.
Allowing connection to a network device that supports the PoE+
standard (IEEE802.3at compliant).
12V
IN (DC 12 V)
Hirose Electric: HA16RA‑4P (77)
Accepts DC 12V inputs from an external power supply.
Input voltage range: 10.8 V to 13.2 V
1
2
3
4
Pin No.
Function
1
GND
2
NC
3
NC
4
+12V