Page 62 highlights

Menu (continued) „„GPI TALLY zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 CAMERA MENU OP 6 GPI TALLY 2 RP SETTING 7 GPIO CAM SEL 3 FILES 8 GPO CAM.G 4 RP INIT 9 GPI PMEM 1 / 1 5 RP VERSION 10 GPI PMEM.G 1 TALLY OUT ON 2 TALLY1 CAM1 TALLY2 CAM2 TALLY3 CAM3 TALLY4 CAM4 3 TALLY5 CAM5 TALLY6 CAM6 TALLY7 CAM7 TALLY8 CAM8 11 4 TALLY9 CAM9 TALLY10 CAM10 ___ indicates factory default settings. Item TALLY OUT*1 TALLY1*1 TALLY2*1 TALLY3*1 TALLY4*1 TALLY5*1 TALLY6*1 TALLY7*1 TALLY8*1 TALLY9*1 Setting value OFF ON CAM1 ⁞ CAM200 CAM1 CAM2 ⁞ CAM200 CAM1 ⁞ CAM3 ⁞ CAM200 CAM1 ⁞ CAM4 ⁞ CAM200 CAM1 ⁞ CAM5 ⁞ CAM200 CAM1 ⁞ CAM6 ⁞ CAM200 CAM1 ⁞ CAM7 ⁞ CAM200 CAM1 ⁞ CAM8 ⁞ CAM200 CAM1 ⁞ CAM9 ⁞ CAM200 Setting details Set whether to send a TALLY notification to the camera if TALLY is input through the port of the TALLY/GPIO 1 connector. ON: Notify OFF: Do not notify Select the camera to send the TALLY notification to when there is an R_TALLY_1 or G_TALLY_1 input through the port of the TALLY/GPIO 1 connector. Select the camera to send the TALLY notification to when there is an R_TALLY_2 or G_TALLY_2 input through the port of the TALLY/GPIO 1 connector. Select the camera to send the TALLY notification to when there is an R_TALLY_3 or G_TALLY_3 input through the port of the TALLY/GPIO 1 connector. Select the camera to send the TALLY notification to when there is an R_TALLY_4 or G_TALLY_4 input through the port of the TALLY/GPIO 1 connector. Select the camera to send the TALLY notification to when there is an R_TALLY_5 or G_TALLY_5 input through the port of the TALLY/GPIO 1 connector. Select the camera to send the TALLY notification to when there is an R_TALLY_6 or G_TALLY_6 input through the port of the TALLY/GPIO 1 connector. Select the camera to send the TALLY notification to when there is an R_TALLY_7 or G_TALLY_7 input through the port of the TALLY/GPIO 1 connector. Select the camera to send the TALLY notification to when there is an R_TALLY_8 or G_TALLY_8 input through the port of the TALLY/GPIO 1 connector. Select the camera to send the TALLY notification to when there is an R_TALLY_9 or G_TALLY_9 input through the port of the TALLY/GPIO 1 connector. *1: This item is saved to the memory card by MAINTENANCE > RP SETTING > DATA SAVE. 62

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98

62
Menu
(continued)
±
GPI TALLY
z
The setting values will vary depending on the connected camera.
CAM01 :
AW-UE150
1 / 1
FILES
RP
SETTING
CAMERA
MENU OP
GPO
CAM.G
GPI
PMEM
GPI
PMEM.G
GPIO
CAM SEL
GPI
TALLY
RP
INIT
RP
VERSION
ON
TALLY OUT
CAM1
TALLY1
CAM2
TALLY2
CAM3
TALLY3
CAM4
TALLY4
CAM5
TALLY5
CAM6
TALLY6
CAM9
TALLY9
CAM10
TALLY10
CAM7
TALLY7
CAM8
TALLY8
1
2
3
4
11
1
2
3
4
7
8
9
5
6
10
___ indicates factory default settings.
Item
Setting value
Setting details
TALLY OUT*
1
OFF
ON
Set whether to send a TALLY notification to the camera if TALLY is input through the port of the
TALLY/GPIO 1 connector.
ON:
Notify
OFF:
Do not notify
TALLY1*
1
CAM1
CAM200
Select the camera to send the TALLY notification to when there is an R_TALLY_1 or G_TALLY_1
input through the port of the TALLY/GPIO 1 connector.
TALLY2*
1
CAM1
CAM2
CAM200
Select the camera to send the TALLY notification to when there is an R_TALLY_2 or G_TALLY_2
input through the port of the TALLY/GPIO 1 connector.
TALLY3*
1
CAM1
CAM3
CAM200
Select the camera to send the TALLY notification to when there is an R_TALLY_3 or G_TALLY_3
input through the port of the TALLY/GPIO 1 connector.
TALLY4*
1
CAM1
CAM4
CAM200
Select the camera to send the TALLY notification to when there is an R_TALLY_4 or G_TALLY_4
input through the port of the TALLY/GPIO 1 connector.
TALLY5*
1
CAM1
CAM5
CAM200
Select the camera to send the TALLY notification to when there is an R_TALLY_5 or G_TALLY_5
input through the port of the TALLY/GPIO 1 connector.
TALLY6*
1
CAM1
CAM6
CAM200
Select the camera to send the TALLY notification to when there is an R_TALLY_6 or G_TALLY_6
input through the port of the TALLY/GPIO 1 connector.
TALLY7*
1
CAM1
CAM7
CAM200
Select the camera to send the TALLY notification to when there is an R_TALLY_7 or G_TALLY_7
input through the port of the TALLY/GPIO 1 connector.
TALLY8*
1
CAM1
CAM8
CAM200
Select the camera to send the TALLY notification to when there is an R_TALLY_8 or G_TALLY_8
input through the port of the TALLY/GPIO 1 connector.
TALLY9*
1
CAM1
CAM9
CAM200
Select the camera to send the TALLY notification to when there is an R_TALLY_9 or G_TALLY_9
input through the port of the TALLY/GPIO 1 connector.
*1: This item is saved to the memory card by MAINTENANCE > RP SETTING > DATA SAVE.