Panasonic AW-RP150GJ AW-RP150 Operation Manual - Operating Instructions - Page 71
Manual Ip Set, Cam Sel, Cam Ip, Upload
View all Panasonic AW-RP150GJ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 71 highlights
Menu (continued) MANUAL IP SET zzThe setting values will vary depending on the connected camera. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 1 / 1 5 RP IP SET 1 CAM SEL 1 2 CAM IP 192 168 3 PORT 80 0 10 UPLOAD NO? 11 ___ indicates factory default settings. Item CAM SEL*1, *2 CAM IP*1, *2 PORT*1, *2 UPLOAD Setting value 1 ⁞ 200 1 ⁞ 80 ⁞ 65535 NO? YES? Setting details Select the camera control number for which you want to configure settings. The setting ranges are as follows. 1 to 200 The network settings for the selected camera control number will appear in the screens that follow. Sets the IP address of the camera. The setting ranges are as follows. (IP addresses are assigned in order starting with 192.168.0.10 for CAM1 under factory default conditions.) Sets the port number of the camera. Turn the F4 dial to select "YES?" and press the F4 dial so the IP address and port number for the camera are set. zzSettings are not updated until [UPLOAD] is executed after the settings are changed. *1: This item is saved to the memory card by MAINTENANCE > RP SETTING > DATA SAVE. *2: This item is saved to the memory card by SYSTEM > CONNECT SETTING > DATA SAVE. 71