Panasonic AW-RP150GJ AW-RP150 Operation Manual - Operating Instructions - Page 30
Network settings of the unit, SUBNET, GATEWAY, NW SET, UPLOAD
View all Panasonic AW-RP150GJ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
Network settings of the unit To control a remote camera connected via an IP connection from the unit, you need to set the network settings of the unit. Note zzCorrect operation is not possible if the same IP address already exists in the same network. The message "IP Duplicate" may be displayed during start up, etc., when duplicate IP addresses have been detected. Set IP addresses that are not duplicates of any existing IP addresses. Setting the IP address of the unit 1. Press the [SYSTEM] button. 2. Touch "RP IP SET" to display the "IP" item. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 1 / 2 5 RP IP SET 1 IP 192 168 2 SUBNET 255 255 3 GATEWAY 192 168 4 NW SET STATIC 5 0 9 255 0 0 1 12 UPLOAD NO? zzThis is set to "192.168.0.9" by default. 3. Use the menu operation dials to set the IP address of the unit to one that is not a duplicate of that of another device. Enter this in 4 blocks of numerals. If "UPLOAD" in the fifth row is not executed, the changes are not updated. zzThe "IP Duplicate" message is displayed when the connection destination IP address of the remote camera is duplicated, and it cannot be registered. Refer to the "Settable addresses" (page 31). Notes zzIn order for the setting to take effect, the unit must be restarted. Turn off the unit's power, and then turn it back on. zzConsult the network administrator before setting the IP address. Setting the subnet mask 1. Press the [SYSTEM] button. 2. Touch "RP IP SET" to display the "SUBNET" item. CAM01 : AW-UE150 1 CAMERA 6 2 CONNECT SETTING TRACKING 3 MANUAL IP SET 4 AUTO IP SET 1 / 2 5 RP IP SET 1 IP 192 168 2 SUBNET 255 255 3 GATEWAY 192 168 4 NW SET STATIC 5 0 9 255 0 0 1 12 UPLOAD NO? zzThis is set to "255.255.255.0" by default. 3. Press the cursor movement buttons to select "SUBNET". zzYou can also select by touching the row number. 4. Use the menu operation dials to set the subnet mask of the unit. Enter this in 4 blocks of numerals. If "UPLOAD" in the fifth row is not executed, the changes are not updated. zz"Unavailable Subnetmask setting" is displayed if a value that cannot be set is entered. Refer to the "Settable addresses" (page 31). Note zzIn order for the setting to take effect, the unit must be restarted. Turn off the unit's power, and then turn it back on. 30