Panasonic WJ-ND300A/10000V Operating Instructions - Page 54

About the Error Log

Page 54 highlights

About the Error Log The following are the descriptions about the contents of the error log and the network error log. Content Error Log Network log Power outage PWR LOSS - detection Recover from a PWR RECOVER - power outage Fan warning FAN u-f - Thermal error THERMAL u-1 - warning Extension mode - - settings error HDD Write error W-ERR u-d - HDD Read error R-ERR u-d - RAID 1 down HDu-d 1DOWN - RAID 2 down HDu 2DOWN - Disk array change - - HDD S.M.A.R.T. SMART u-d - warning HDD hour meter H.METER u-d - warning *1 Volume Error V-ERROR vvv - HDD SKIP warning *2 SKIP HDD u-d - Remove auto REMOVE u-d - links HDD error under HDD HDu-d RCVR-ERR e - RAID 5 recovery HDD RAID5 R-FAIL u - failure EVENT area EVT-**% - available capacity warning EVENT area EVT-FULL - available capacity warning (FULL) COPY area CPY-**% - available capacity warning COPY area CPY-FULL - available capacity warning (FULL) Copy error NO DATA CPY - HDD RAID board initialization failure Indication on the LCD SYS-1 ERR POWER FAILURE - Output from the connector on the rear panel - - FAN-1-u-f ERR Error output FAN ERROR TML-1-u-1 ERR Error output THERMAL ERROR SYS-2 SINGLE - RAID MIX ERROR - - - - HDD-10 ERR HDD error output RAID5 1DOWN - HDD error output Please Setup on - DISK CONFIG MENU HDD-1-u-d ERR HDD error output HDD WARNING HDD-2-u-d ERR HDD error output HDD HOUR METER - HDD error output - HDD error output HDD-3-u-d ERR HDD error output HDD REMOVED - - HDD-4-u ERR HDD error output RAID5 RECOVERY - Copy/event recording area available capacity warning output HDD-5 ERR Copy/event recording EVENT-HDD FULL area available capacity warning output - Copy/event recording area available capacity warning output HDD-6 ERR Copy/event recording COPY-HDD FULL area available capacity warning output - - HDD-9 ERR RAID INITIAL ERR *1: In the RAID 5 mode, only "Error Log" is displayed, but neither "Indication on the LCD" nor "Output from the connector on the rear panel" is displayed. *2: "HDD SKIP" is the function that continues recording even when an error occurs, such as an HDD write error, by recording images on the next HDD. 54

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

54
About the Error Log
The following are the descriptions about the contents of the error log and the network error log.
Content
Power outage
detection
Error Log
Network log
Indication on
the LCD
Output from the connec-
tor on the rear panel
PWR LOSS
SYS-1 ERR
POWER FAILURE
Recover from a
power outage
PWR RECOVER
Fan warning
FAN u-f
FAN-1-u-f ERR
FAN ERROR
Error output
Thermal error
warning
THERMAL u-1
TML-1-u-1 ERR
THERMAL ERROR
Error output
Extension mode
settings error
SYS-2 SINGLE
RAID
MIX ERROR
HDD Write error
W-ERR u-d
HDD Read error
R-ERR u-d
RAID 1 down
HDu-d 1DOWN
HDD-10 ERR
RAID5 1DOWN
HDD error output
RAID 2 down
HDu 2DOWN
HDD error output
Disk array change
Please Setup on
DISK CONFIG MENU
HDD S.M.A.R.T.
warning
SMART u-d
HDD-1-u-d ERR
HDD WARNING
HDD error output
HDD hour meter
warning *
1
Volume Error
HDD SKIP warning
*
2
H.METER u-d
V-ERROR vvv
SKIP HDD u-d
HDD-2-u-d ERR
HDD HOUR METER
HDD error output
HDD error output
HDD error output
Remove auto
links
HDD error under HDD
RAID 5 recovery
REMOVE u-d
HDu-d RCVR-ERR e
HDD-3-u-d ERR
HDD REMOVED
HDD error output
HDD RAID5
failure
R-FAIL u
HDD-4-u ERR
RAID5 RECOVERY
HDD error output
EVENT area
available capacity
warning
EVT-**%
Copy/event recording
area available capacity
warning output
EVENT area
available capacity
warning (FULL)
EVT-FULL
HDD-5 ERR
EVENT-HDD FULL
Copy/event recording
area available capacity
warning output
COPY area
available capacity
warning
CPY-**%
Copy/event recording
area available capacity
warning output
COPY area
available capacity
warning (FULL)
Copy error
CPY-FULL
NO DATA CPY
HDD-6 ERR
COPY-HDD FULL
Copy/event recording
area available capacity
warning output
HDD RAID board
initialization failure
HDD-9 ERR
RAID INITIAL ERR
*1: In the RAID 5 mode, only "Error Log" is displayed, but neither "Indication on the LCD" nor "Output from the con-
nector on the rear panel" is displayed.
*2: "HDD SKIP" is the function that continues recording even when an error occurs, such as an HDD write error, by
recording images on the next HDD.