    EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-XC50/55 Ver. 1.00 SANYO Electric Co., Ltd DS Company Projector Division
  • Sanyo PLC-XC50A | RS232C Extend - Page 2
    PLC-XC50/55 Expand Serial Command Functional Specifications - CONTENTS 1. Overview ...8 2. Serial Interface Specification 8 2.1 Transfer Specification Read Command Table 12 6.5 Screen Status Read Command Table 13 6.6 Lamp Status Read Command Table 13 6.7 Sound Status Read Command Table 13
  • Sanyo PLC-XC50A | RS232C Extend - Page 3
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.4.9 CF_PROGV Command 18 8.4.10 CF_NZRED Command 18 8.4.11 CF_IMAGE CF_VPOS Command 29 8.7.7 CF_HSCALE Command 29 8.7.8 CF_HPOS Command 30 8.8 Lamp Command 31 8.8.1 CF_LAMPH Command 31 8.8.2 CF_LAMPMODE Command 31 8.9 Sound
  • Sanyo PLC-XC50A | RS232C Extend - Page 4
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.10.3 CF_AUTOSETUPKEYSTONE Command 33 8.10.4 CF_AUTOSETUP Command 34 8.10.5 CF_INPUTSEARCH Command 34 8.10.6 CF_BBACK Command 34 8.10.7 CF_DISP Command 34 8.10.8 CF_LOGO Command 35 8.10.9
  • Sanyo PLC-XC50A | RS232C Extend - Page 5
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.4.6 CR_GAMMA Command 44 9.4.7 CR_WBAL - R Command 44 9.4.8 CR_WBAL - G Command 44 9.8.6 CR_HPOS Command 54 9.9 Lamp Status Read Command 55 9.9.1 CR_LAMPREPL Command 55 9.9.2 CR_LAMPH Command 55 9.9.3 CR_LAMPCORRESPH Command 55 5/67
  • Sanyo PLC-XC50A | RS232C Extend - Page 6
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.9.4 CR_LAMPMODE Command 55 9.9.5 CR_LAMPMSTS Command 56 9.9.6 CR_PROJH Command 56 9.9.7 CR_HMLAMP Command 56 9.10 Sound Status Read Command 57 9.10.1 CR_VOLUME Command 57 9.10.2 CR_MUTE Command 57 9.11 Setting
  • Sanyo PLC-XC50A | RS232C Extend - Page 7
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.12.6 9.12.7 9.12.8 CR_TEMPWARN Command 65 CR_TEMP Command 66 CR_TEMPFAIL Command 67 7/67
  • Sanyo PLC-XC50A | RS232C Extend - Page 8
    PLC-XC50/55 Expand Serial Command Functional Specifications 1. Overview 1.1 This Functional Specification defines communication functions for PLC-XC50/55 1.2 Compatible to Firmware Ver. 1.x of the projector. 1.3 Most commands can be used to control projector remotely from PC by RS-232C. Therefore,
  • Sanyo PLC-XC50A | RS232C Extend - Page 9
    PLC-XC50/55 Expand Serial Command Functional Specifications 3. Notes for communication 3.1 Expand Serial Command is When it takes more than one second to receive carriage return (0X0D) after the projector receives the first data "C", it clears the information of buffer. 3.4 On command pipelining
  • Sanyo PLC-XC50A | RS232C Extend - Page 10
    PLC-XC50/55 Expand Serial Command Functional Specifications 5. Functional Execution Command Table 5.1 Image Command Table Execute command CF_BRIGHT_%1[CR] CF_CONT_%1[CR] CF_COLOR_%1[CR] CF_TINT_%1[CR] CF_SHARP_%1[CR] CF_GAMMA_%1[CR] CF_WBAL-R_%1[CR] CF_WBAL-
  • Sanyo PLC-XC50A | RS232C Extend - Page 11
    PLC-XC50/55 Expand Serial Command Functional Specifications 5.5 Lamp Command Table Execute command CF_LAMPH_%1[CR] CF_LAMPMODE_%1[CR] Item Reset total running time of each lamp Select Lamp mode 5.6 Sound Command Table Execute command CF_VOLUME_%1[CR] CF_MUTE_%1[CR] Item Set Volume value Control
  • Sanyo PLC-XC50A | RS232C Extend - Page 12
    PLC-XC50/55 Expand Serial Command Functional Specifications 6. Status Read Command Table 6.1 Image Status Read Command Table Status read command CR_BRIGHT[CR] CR_CONT[CR] CR_COLOR[CR] CR_TINT[CR] CR_SHARP[CR] CR_GAMMA[CR] CR_WBAL-R[
  • Sanyo PLC-XC50A | RS232C Extend - Page 13
    PLC-XC50/55 Expand Serial Command Functional Specifications 6.5 Screen Status Read Command Table Status read command for Lamp replacement time Get lamp total running time Get corresponding lamp use time Get Lamp Mode status Get lamp lighting status Get projector total running time Get lamp number
  • Sanyo PLC-XC50A | RS232C Extend - Page 14
    PLC-XC50/55 Expand Serial Command Functional Specifications 6.9 Other Status Read Command Status read command CR_STATUS[CR] CR_SIGNAL[CR] CR_VMUTE[CR] CR_FREEZE[CR] CR_PTIMER[CR] CR_TEMPWARN[CR] CR_TEMP[CR] CR_TEMPFAIL[CR] Item Get setting status of Projector behavior Get Signal Status if there
  • Sanyo PLC-XC50A | RS232C Extend - Page 15
    PLC-XC50/55 Expand Serial Command Functional Specifications 8. Functional Execution Command 8.1 Format 1) PC issues commands in format as below: Pattern1 POWER OFF CF POWER ON CF POWER OFF Note:) When the projector receives the other command in this above status, it returns error code to show the
  • Sanyo PLC-XC50A | RS232C Extend - Page 16
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.4 Image Command 8.4.1 CF_BRIGHT Command Command "CF_BRIGHT_%1"[CR] setting value - 1 Details Set Tint value of user control The value set by this command will not be saved to projector. Therefore, when turning into Standby-mode or ALL
  • Sanyo PLC-XC50A | RS232C Extend - Page 17
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.4.5 CF_SHARP Command Command "CF_SHARP_%1"[CR] "000~015 Directly select Sharpness setting value %1 "UP Current Sharpness setting value + 1 "DN Current Sharpness setting value - 1 Details Set Sharpness value of user control The
  • Sanyo PLC-XC50A | RS232C Extend - Page 18
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.4.8 CF_COLTEMP Command Command "CF_COLTEMP_%1"[CR] "000" ------ Xlow / cancel Progressive scan The value set by this command will not be saved to projector. Therefore, when turning into Standby-mode or ALL is OFF, the value returns to
  • Sanyo PLC-XC50A | RS232C Extend - Page 19
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.4.11 CF_IMAGE Command Command "CF_IMAGE_%1"[CR] user) "CUSTOM2" ----- Image2 (the value set and stored by a user) "CUSTOM3" ----- Image3 (the value set and stored by a user) "CUSTOM4" ----- Image4 (the value set and stored by a user
  • Sanyo PLC-XC50A | RS232C Extend - Page 20
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.5 PC Adjust Control Command 8.5.1 CF_FSYNC Command Command " Total Dots of PC signal The value set by this command will not be saved to projector. Therefore, when turning into Standby mode or ALL is OFF, the value returns to original
  • Sanyo PLC-XC50A | RS232C Extend - Page 21
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.5.4 CF_H - POS Command Command "CF_H-POS_%1"[CR] "0000~nnnn" Dots value of PC signal The value set by this command will not be saved to projector. Therefore, when turning into Standby mode or ALL is OFF, the value returns to original
  • Sanyo PLC-XC50A | RS232C Extend - Page 22
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.5.7 CF_DLINE Command Command "CF_DLINE_%1"[CR] "0100"~"nnnn" --- Line value of PC signal The value set by this command will not be saved to projector. Therefore, when turning into Standby mode or ALL is OFF, the value returns to
  • Sanyo PLC-XC50A | RS232C Extend - Page 23
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.6 Input Control Command 8.6.1 CF_INPUT Command Command "CF_INPUT_%1"[CR Details Select Input The same operation as "INPUT" button of the projector and Remote Control. This command is available in normal Power ON status. When Computer
  • Sanyo PLC-XC50A | RS232C Extend - Page 24
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.6.3 CF_INPUT1 Command Command "CF_INPUT1_%1_"[CR] "ANALOG" ----------Select Analog RGB Input %1 "DIGITAL Select DVI Input "HDCP Select DVI HDCP Input Details "ANALOG" selects Input - Computer 1(
  • Sanyo PLC-XC50A | RS232C Extend - Page 25
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.6.6 CF_INPUT_%1_%2 Command Command "CF_INPUT_%1_%2"[CR] "COMPUTER1" ------ Select Computer1 Input %1 "COMPUTER2" ------ Select Computer2 Input "VIDEO Select Analog Input When %1 is COMPUTER1 "ANALOG" ----- Select Analog
  • Sanyo PLC-XC50A | RS232C Extend - Page 26
    PLC-XC50/55 Expand Serial Command Functional Specifications Details Response Input is Video "AUTO Select of currently selected Input When Input specified by %1 is inappropriate for selected Input, the projector returns "101"[CR] and the command is not executed This command is available in normal
  • Sanyo PLC-XC50A | RS232C Extend - Page 27
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.7 Screen Control Command 8.7.1 CF_SCREEN Command Command "CF_SCREEN_%1"[CR size on screen. When Input specified by %1 is inappropriate for selected Input, the projector returns "101" [CR] and the command is not executed. "DZOOM UP" and
  • Sanyo PLC-XC50A | RS232C Extend - Page 28
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.7.3 CF_KEYSTONE Command Command "CF_KEYSTONE_%1"[CR] "UP Correct Keystone distortion to reduce upper part of image "FUP Correct Keystone distortion to reduce upper part by 2steps %1 "DN Correct Keystone distortion to reduce lower
  • Sanyo PLC-XC50A | RS232C Extend - Page 29
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.7.6 CF_VPOS Command Command "CF_VPOS_%1"[CR] "015 15 "014 14 "002 2 "001 Screen setting is not Custom, projector returns 101[CR] and the command does not execute. Note2) When there is no Input, projector returns 101 and the command
  • Sanyo PLC-XC50A | RS232C Extend - Page 30
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.7.8 CF_HPOS Command Command "CF_HPOS_%1"[CR] "015 15 "014 14 "002 2 "001 Screen setting is not Custom, projector returns 101[CR] and the command does not execute. Note2) When there is no Input, projector returns 101 and the command
  • Sanyo PLC-XC50A | RS232C Extend - Page 31
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.8 Lamp Command 8.8.1 CF_LAMPH Command Command "CF_LAMPH_%1"[CR] %1 "RST" Details Reset total lamp running time This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.8.2
  • Sanyo PLC-XC50A | RS232C Extend - Page 32
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.9 Sound Command 8.9.1 CF_VOLUME Command Command "CF_VOLUME_%1"[CR] " the Sound Mute is released. The value set by this command is stored to Projector. This command is available in normal Power ON status. Acceptable "000"[CR] Response
  • Sanyo PLC-XC50A | RS232C Extend - Page 33
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.10 Setting Command 8.10.1 CF_LANG Command Command "CF_LANG_%1"[CR] "ENG Select English "DEU Select German "FRA Select French "ITA Select Italian "ESP Select Spanish "POR
  • Sanyo PLC-XC50A | RS232C Extend - Page 34
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.10.4 CF_AUTOSETUP Command Command "CF_AUTOSETUPPCADJ_%1"[CR be set "Off" at the same time. When Keystone and PC adj. are Off, projector returns error code "101" by receiving this command. Acceptable "000"[CR] Response Unacceptable "Error
  • Sanyo PLC-XC50A | RS232C Extend - Page 35
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.10.8 CF_LOGO Command Command "CF_LOGO_%1_%2"[CR] %1 "0000"-"9999 Set LOGO PIN CODE directly "OFF Disable Logo function "DFLT Display Default Logo "USER LOCK continues.) Projector returns Error Code "101" by receiving USER in %2
  • Sanyo PLC-XC50A | RS232C Extend - Page 36
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.10.10 CF_REAR Command Command "CF_REAR_%1"[CR] %1 "ON Set Rear to ON "OFF Set Rear to OFF Details Set/Cancel Rear setting. When Rear is
  • Sanyo PLC-XC50A | RS232C Extend - Page 37
    PLC-XC50/55 Expand Serial Command Functional Specifications is effective after ALL is OFF. This command is available when projector is in normal Power ON status and its condition is; "CF_FILH_%1"[CR] %1 "RST Reset Filter used time Details Reset filter used time Acceptable "000"[CR] Response
  • Sanyo PLC-XC50A | RS232C Extend - Page 38
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.10.18 CF_FILTIMER Command Command "CF_FILTIMER_%1"[CR] "400 Set 400 hours %1 "700 Set 700 hours "1000 Set 1000 hours "OFF No warning display Details Set timer of Warning display of Filter cleaning and Filter replacement
  • Sanyo PLC-XC50A | RS232C Extend - Page 39
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.10.23 CF_PJPINCODE Command Command "CF_PJPINCODE_%1"[CR Also when PJ LOCK setting is "On1", it is necessary to transmit this command everytime lamp turns on. Acceptable "000"[CR] Unacceptable "Error Code"[CR] 8.10.24 CF_FANMODE Command
  • Sanyo PLC-XC50A | RS232C Extend - Page 40
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.11 Other Command 8.11.1 CF_KEYENU Command Command "CF_KEYENU_ command behave the same as corresponding keys of Remote Control / Projector Auto PC adj. keeps operating even though projector receives this command again while Auto PC adj.
  • Sanyo PLC-XC50A | RS232C Extend - Page 41
    PLC-XC50/55 Expand Serial Command Functional Specifications 8.11.4 CF_FREEZE Command Command "CF_FREEZE_%1"[CR] "ON Set Freeze to ON " Cancel P-TIMER This command behaves the same as "P-TIMER" key of Remote Control / Projector. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 41/67
  • Sanyo PLC-XC50A | RS232C Extend - Page 42
    PLC-XC50/55 Expand Serial Command Functional Specifications 9. Status Read Command 9.1 Format 1) PC issues commands in format as below: "CR_Command" [CR] Command : Character Line 2) When projector receives the appropriate command, it returns a character line as the required data "000 "%1 [CR] %1:
  • Sanyo PLC-XC50A | RS232C Extend - Page 43
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.4 Image Status Read Command 9.4.1 CR_BRIGHT Command Command "CR_BRIGHT"[CR] Details Get Brightness value of user control Acceptable "000_ "[CR] Response %a "000"~"063" Unacceptable "Error Code"[CR] 9.4.2 CR_CONT Command Command
  • Sanyo PLC-XC50A | RS232C Extend - Page 44
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.4.6 CR_GAMMA Command Command "CR_GAMMA"[CR] Details Get Gamma value of user control Acceptable "000_%a"[CR] Response %a "000"~"015" Unacceptable "Error Code"[CR] 9.4.7 CR_WBAL - R Command Command "CR_WBAL-R"[CR] Details Get
  • Sanyo PLC-XC50A | RS232C Extend - Page 45
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.4.11 CR_NZRED Command Command "CR_NZRED"[CR] Details Get setting status of Noise Reduction Acceptable "000_%1"[CR] "L1" -------- Noise Reduction for moving image Response %1 "L2" -------- Noise
  • Sanyo PLC-XC50A | RS232C Extend - Page 46
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.5 PC Adjust Status Read Command 9.5.1 CR_FSYNC Command Command "CR_FSYNC"[CR] Details Get Fine Sync value Acceptable "000_%a"[CR] Response %a Unacceptable "0000"~"0031" "Error Code"[CR] -----
  • Sanyo PLC-XC50A | RS232C Extend - Page 47
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.5.5 CR_V - POS Command Command "CR_V - POS"[CR] Details Get Vertical Position value Acceptable "000_%a"[CR] Response %a "0000"~"nnnn" (nnnn = Total Line - Display Line) Unacceptable "Error
  • Sanyo PLC-XC50A | RS232C Extend - Page 48
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.6 Video Status Read Command 9.6.1 CR_SERSYS Command Command "CR_SERSYS"[CR] Details Get currently selected signal Returns auto-detected signal in Auto mode Only available for Video
  • Sanyo PLC-XC50A | RS232C Extend - Page 49
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.7 Input Status Read Command 9.7.1 CR_INPUT Command Command "CR_INPUT"[CR] Details Get selected INPUT No. Acceptable "000_%1"[CR] Response Request data "1"-"3" Unacceptable "Error Code"[CR] 9.7.2 CR_SOURCE
  • Sanyo PLC-XC50A | RS232C Extend - Page 50
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.7.5 CR_SRCINP3 Command Command "CR_SRCINP3" [CR] Details is selected "D 575I D-575i is selected "D 480I D-480i is selected When there is no signal, projector returns error code"101" [CR] Input is Y,Pb/Cb,Pr /Cr "AUTO Auto is selected
  • Sanyo PLC-XC50A | RS232C Extend - Page 51
    PLC-XC50/55 Expand Serial Command Functional Specifications Input is Video, S-Video Unacceptable "AUTO Auto is selected "NTSC NTSC is selected "NTSC443 NTSC4.43 is selected "PAL PAL is selected "SECAM SECAM is selected "PAL M PAL-M is selected "PAL N AL-N is selected Projector "D-XGA D -XGA
  • Sanyo PLC-XC50A | RS232C Extend - Page 52
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.7.8 CR_MODELIST Command Command "CR_MODELIST"[CR] Details Get selectable Mode titles Acceptable "000_%1_%2_..._%x" [CR] Returns Error code "101" when Input is other than PC-
  • Sanyo PLC-XC50A | RS232C Extend - Page 53
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.8 Screen Status Read Command 9.8.1 CR_SCREEN Command Command %a PC "CUSTOM Custom mode is selected When the screen is set to D.Zoom, projector returns the previous status (NORMAL ) Input "NORMAL Normal mode is selected is "WIDE
  • Sanyo PLC-XC50A | RS232C Extend - Page 54
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.8.6 CR_HPOS Command Command "CR_HPOS"[CR] Details Get setting status of Horizontal Position Store Mode Acceptable "000_%1"[CR] Response %1 "-15" ~ "015" Unacceptable "Error Code"[CR] 54/67
  • Sanyo PLC-XC50A | RS232C Extend - Page 55
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.9 Lamp Status Read Command 9.9.1 CR_LAMPREPL Command Command "CR_LAMPREPL"[CR] Details Get information of Lamp Replacement time Acceptable "000_%1"[CR] "1Y Over lamp replacement time "1N Within lamp replacement time Response %1 "1"
  • Sanyo PLC-XC50A | RS232C Extend - Page 56
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.9.5 CR_LAMPMSTS Command Command "CR_LAMPSTS"[CR] Details Get Lighting status of lamp Acceptable "000_%1"[CR] " **** " A number of * should be among 1-4. First character shows how many lamps are incorporated in projector. (1,2 or 4
  • Sanyo PLC-XC50A | RS232C Extend - Page 57
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.10 Sound Status Read Command 9.10.1 CR_VOLUME Command Command "CR_VOLUME"[CR] Details Get Volume value of user control Acceptable "000_%a"[CR] Response %a "000"~"063" Unacceptable "Error Code"[CR] 9.10.2 CR_MUTE Command Command
  • Sanyo PLC-XC50A | RS232C Extend - Page 58
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.11 Setting Status Read Command 9.11.1 CR_LANG Command Command " Acceptable "000_%a"[CR] "AUTO Auto Keystone is Auto Response %a "MANUAL Auto Keystone is Manual "OFF Auto Keystone is OFF Unacceptable "Error Code"[CR] 9.11.4
  • Sanyo PLC-XC50A | RS232C Extend - Page 59
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.11.5 CR_BBACK USER User Logo is selected Unacceptable "Error Code"[CR] 9.11.8 CR_CEIL Command Command "CR_CEIL" [CR] Details Get setting status of Ceiling Acceptable "000_%1"[CR] Response %1 "ON Ceiling is ON "OFF Ceiling
  • Sanyo PLC-XC50A | RS232C Extend - Page 60
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.11.10 CR_STANDBYMODE Command Command "CR_STANDBYMODE" [CR] Details Get Standby Mode setting status Acceptable "000_%a"[CR] Response %a "ECO Eco Mode "NORMAL" -------- Normal Mode Unacceptable "Error
  • Sanyo PLC-XC50A | RS232C Extend - Page 61
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.11.15 CR_CCAPTIONCOLOR Command Command "CR_ Command Command "CR_FILTIMER" [CR] Details Get setting status of timer for Filter cleaning / replacement warning Acceptable "000_%1" [CR] Response "0400 Display massage by 400h
  • Sanyo PLC-XC50A | RS232C Extend - Page 62
    PLC-XC50/55 Expand Serial Command Functional Specifications Response Acceptable "000_%1" [CR] %1 "09" = Remaining number of usable Filter scroll : 9 times "00" = Remaining number of usable Filter and PJ PIN CODE is not entered so that projector is actually locked. Response %1 "FREE PJ Lock
  • Sanyo PLC-XC50A | RS232C Extend - Page 63
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.11.25 CR_ PJLOCKMENU Command Command "CR_PJLOCKMENU" [CR] Details Get status of PJ Lock on Menu Acceptable "000_%1[CR] "ON1 PJ Lock status is On-1
  • Sanyo PLC-XC50A | RS232C Extend - Page 64
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.12 Other Status Read Command 9.12.1 CR_STATUS Command Command "CR_STATUS"(CR) Details Get status of Projector Lamp failure "81"= Stand by after Cooling down due to Lamp failure -------- No Show is ON, User Logo (My picture) is
  • Sanyo PLC-XC50A | RS232C Extend - Page 65
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.12.5 "CR_TEMPWARN"[CR] Details Get the temperature inside a projector and its condition if it is abnormal temperature or 1 and 3 reaches specific value, some of the models detect it as Abnormal temperature. In this case, the 3rd data
  • Sanyo PLC-XC50A | RS232C Extend - Page 66
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.12.7 CR_TEMP Command Command "CR_TEMP"[CR] Details Get current temperature inside a projector is close to abnormal temp. In case projector cannot return its data due to some projectors get abnormal temperature because of heat of Lamp
  • Sanyo PLC-XC50A | RS232C Extend - Page 67
    PLC-XC50/55 Expand Serial Command Functional Specifications 9.12.8 CR_TEMPFAIL Command Command "CR_TEMPFAIL"[CR] Details Get the temperature inside a projector when abnormal temperature occurs. If there are several sensors installed, it is possible to get information from all the sensors at once
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67

EXPAND SERIAL COMMAND
FUNCTIONAL SPECIFICATIONS
PLC-XC50/55
Ver. 1.00
SANYO Electric Co., Ltd