Sanyo PLC-XC50A RS232C Extend - Page 46
PC Adjust Status Read Command, CR_FSYNC Command, CR_TDOTS Command, CR_CLAMP Command, CR_H - POS
View all Sanyo PLC-XC50A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
PLC-XC50/55 Expand Serial Command Functional Specifications 9.5 PC Adjust Status Read Command 9.5.1 CR_FSYNC Command Command "CR_FSYNC"[CR] Details Get Fine Sync value Acceptable "000_%a"[CR] Response %a Unacceptable "0000"~"0031" "Error Code"[CR] ----- The command is invalid due to condition such as invalid input source 9.5.2 CR_TDOTS Command Command "CR_TDOTS"[CR] Details Get Total Dots value Acceptable "000_%a"[CR] "nnnn"~"mmmm" Response %a (nnnn = Display Dots + Horizontal Position) (mmmm= Maximum value depends on input signal) Unacceptable "Error Code"[CR] ----- The command is invalid due to condition such as invalid input source 9.5.3 CR_CLAMP Command Command "CR_CLAMP"[CR] Details Get Clamp value Acceptable "000_%a"[CR] Response %a "0001"~"nnnn" ("nnnn" depends on input signal) Unacceptable "Error Code"[CR] ----- The command is invalid due to condition such as invalid input source 9.5.4 CR_H - POS Command Command "CR_H - POS"[CR] Details Get Horizontal Position value Acceptable "000_%a"[CR] Response %a "0000"~"nnnn" (nnnn = Total Dots - Display Dots) Unacceptable "Error Code"[CR] ----- The command is invalid due to condition such as invalid input source 46/67