Sanyo PLC-XC50A RS232C Extend - Page 60
CR_STANDBYMODE Command, 11.11 CR_P - MANE Command, 11.12 CR_P - MANETIME Command, 11.13 CR_ON-
View all Sanyo PLC-XC50A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
PLC-XC50/55 Expand Serial Command Functional Specifications 9.11.10 CR_STANDBYMODE Command Command "CR_STANDBYMODE" [CR] Details Get Standby Mode setting status Acceptable "000_%a"[CR] Response %a "ECO Eco Mode "NORMAL" -------- Normal Mode Unacceptable "Error Code" [CR] 9.11.11 CR_P - MANE Command Command "CR_P-MANE"[CR] Details Get Power management setting status Acceptable "000_%a"[CR] "OFF Power Management is OFF Response %a "READY Power Management is Ready "SHUTDOWN Power Management is set to Shut Down mode Unacceptable "Error Code" [CR] 9.11.12 CR_P - MANETIME Command Command "CR_P-MANETIME"[CR] Details Get time to start Power Management Acceptable "000_%a"[CR] Response %a "001"~"030 1 minute to 30 minutes Unacceptable "Error Code" [CR] 9.11.13 CR_ON-STA Command Command "CR_ON-STA"[CR] Details Get Power ON Start setting status Acceptable "000_%a"[CR] Response %a "ON Power ON Start is ON "OFF Power ON Start is OFF Unacceptable "Error Code" [CR] 9.11.14 CR_CCAPTIONDISP Command Command "CR_CCAPTIONDISP"[CR] Details Get selected channel of Closed caption channel Acceptable "000_%a"[CR] "OFF Closed caption is Off "CC1 Channel CC1 is selected Response %a "CC2 Channel CC2 is selected "CC3 Channel CC3 is selected "CC4 Channel CC4 is selected Unacceptable "Error Code" [CR] 60/67