PLC-XC50/55 Expand Serial Command Functional Specifications 8.10.8 CF_LOGO Command Command "CF_LOGO_%1_%2"[CR] %1 "0000"-"9999 Set LOGO PIN CODE directly "OFF Disable Logo function "DFLT Display Default Logo "USER Display Captured Logo %2 "UP Switch Logo setting in forward direction (OFF -- DFLT -- User - OFF...) "DN Switch Logo setting in backward direction (OFF -- User -- DFLT - OFF...) Set / Cancel Logo The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF This command is available in normal Power ON status. %1--- Set LOGO PIN CODE Details - When LOGO LOCK is in operation PIN CODE is correct Command is valid (Acceptable) PIN CODE is incorrect Command is invalid (Error Code "102") PIN CODE is out of %1 range ------ Command is invalid (Error Code "? ") -When LOGO LOCK is not in operation PIN CODE is within %1 range ------ Command is valid PIN CODE is out of %1 range ------ Command is invalid (Error Code "? ") Note) Receiving correct LOGO PIN CODE while LOGO LOCK is in operation enables to change LOGO setting, but it does not release LOGO LOCK. (LOGO LOCK continues.) Projector returns Error Code "101" by receiving USER in %2 when capture has not operated. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.10.9 CF_CEIL Command Command "CF_CEIL_%1"[CR] %1 "ON Set Ceiling to ON "OFF Set Ceiling to OFF Details Set/Cancel Ceiling setting. The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 35/67

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67

PLC-XC50/55 Expand Serial Command Functional Specifications
35/67
8.10.8 CF_LOGO Command
Command
“CF_LOGO_%1_%2”[CR]
%1
“0000”-”9999” ----------------- Set LOGO PIN CODE directly
%2
“OFF” ---------------------------- Disable Logo function
“DFLT” --------------------------- Display Default Logo
“USER” -------------------------- Display Captured Logo
“UP” --------------- Switch Logo setting in forward direction
(OFF -- DFLT -- User – OFF…)
“DN” --------------- Switch Logo setting in backward direction
(OFF -- User -- DFLT – OFF…)
Details
Set / Cancel Logo
The value set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF
This command is available in normal Power ON status.
%1--- Set LOGO PIN CODE
- When LOGO LOCK is in operation
PIN CODE is correct ------------------ Command is valid (Acceptable)
PIN CODE is incorrect ---------------- Command is invalid (Error Code “102”)
PIN CODE is out of %1 range ------ Command is invalid (Error Code “? “)
-When LOGO LOCK is not in operation
PIN CODE is within %1 range ------ Command is valid
PIN CODE is out of %1 range ------ Command is invalid (Error Code “? “)
Note) Receiving correct LOGO PIN CODE while LOGO LOCK
is in operation
enables to change LOGO setting, but it does not release LOGO LOCK. (LOGO
LOCK continues.)
Projector returns Error Code “101” by receiving USER in %2 when capture has
not operated.
Response
Acceptable
“000”[CR]
Unacceptable
“Error Code”[CR]
8.10.9 CF_CEIL Command
Command
“CF_CEIL_%1”[CR]
%1
“ON” ------------------------ Set Ceiling to ON
“OFF” ----------------------- Set Ceiling to OFF
Details
Set/Cancel Ceiling setting.
The value set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF
This command is available in normal Power ON status.
Response
Acceptable
“000”[CR]
Unacceptable
“Error Code”[CR]