PLC-XC50/55 Expand Serial Command Functional Specifications 9.12.5 CR_PTIMER Command Command "CR_PTIMER"[CR] Details Get status of Presentation Timer Acceptable "000_%a"[CR] "ON Presentation timer is in operation Response %a "STOP Presentation timer is paused "OFF Presentation timer is not operating Unacceptable "Error Code"[CR] 9.12.6 CR_TEMPWARN Command Command "CR_TEMPWARN"[CR] Details Get the temperature inside a projector and its condition if it is abnormal temperature or close to abnormal temperature If there are several sensors installed, it is possible to get information from all the sensors at once. Acceptable "000_%a_%b_%c"[CR] %a Sensor 1 status %b Sensor 2 status %c Sensor 3 status "W" ---- Approach or reach abnormal temperature (dangerous temperature) "S" ---- Far from abnormal temperature (safe temperature) "N" ---- Sensor detects no abnormal temperature Response %a %b %c [Example] "S_W_S"[CR] means Sensor 1 detects safe temperature, Sensor 2 detects abnormal temperature and Sensor 3 detects safe temperature Note) When the temperature difference between Sensor 1 and 3 reaches specific value, some of the models detect it as Abnormal temperature. In this case, the 3rd data shows if the temperature difference between Sensor 1 and 3 is dangerous state or not. The 3rd data means temperature abnormality due to Sensor 3 When abnormal temperature is not detected by sensor, "N" (No connection with temperature abnormality) is returned. Unacceptable "Error Code"[CR] 65/67

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67

PLC-XC50/55 Expand Serial Command Functional Specifications
65/67
9.12.5 CR_PTIMER Command
Command
"CR_PTIMER”[CR]
Details
Get status of Presentation Timer
Response
Acceptable
“000_%a”[CR]
%a
“ON” -------------------- Presentation timer is in operation
“STOP” ----------------- Presentation timer is paused
“OFF” ------------------- Presentation timer is not operating
Unacceptable
“Error Code”[CR]
9.12.6 CR_TEMPWARN Command
Command
“CR_TEMPWARN”[CR]
Details
Get the temperature inside a projector and its condition if it is abnormal
temperature or close to abnormal temperature
If there are several sensors installed, it is possible to get information from all the
sensors at once.
Response
Acceptable
“000_%a_%b_%c”[CR]
%a
%b
%c
%a -------------------- Sensor 1 status
%b -------------------- Sensor 2 status
%c -------------------- Sensor 3 status
“W” ---- Approach or reach abnormal temperature
(dangerous temperature)
“S” ---- Far from abnormal temperature (safe temperature)
“N” ---- Sensor detects no abnormal temperature
[Example]
“S_W_S”[CR] means Sensor 1 detects safe temperature, Sensor
2 detects abnormal temperature and Sensor 3 detects safe
temperature
Note) When the temperature difference between Sensor 1 and 3
reaches specific value, some of the models detect it as Abnormal
temperature. In this case, the 3rd data shows if the temperature
difference between Sensor 1 and 3 is dangerous state or not. The
3rd data means temperature abnormality due to Sensor 3
When abnormal temperature is not detected by sensor, “N” (No
connection with temperature abnormality) is returned.
Unacceptable
“Error Code”[CR]