Sanyo PLC-XC50A RS232C Extend - Page 32
Sound Command, CF_VOLUME Command, CF_MUTE Command
View all Sanyo PLC-XC50A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
PLC-XC50/55 Expand Serial Command Functional Specifications 8.9 Sound Command 8.9.1 CF_VOLUME Command Command "CF_VOLUME_%1"[CR] "000-063 Directly set Volume level %1 "UP Turn up the Volume level by 1 "DN Turn down Volume level by 1 Details Control Volume value As the same operation of Volume Up/Down with RC, the command directly set Volume level. When setting Volume, the Sound Mute is released. The value set by this command is stored to Projector. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.9.2 CF_MUTE Command Command "CF_MUTE_%1"[CR] %1 "ON Set Sound Mute to ON "OFF Set Sound Mute to OFF Details Control Sound Mute ON/OFF This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 32/67