Adaptec LSM-FC2002 Installation Guide - Page 31
Air Flow, Mechanical Loading, CAUTION: When installing or removing a rack mount enclosure
UPC - 760884145067
View all Adaptec LSM-FC2002 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
31 Air Flow To ensure that the internal heat build up is properly dissipated into the room environment, air flow should in no way be restricted. It is essential that no air vents are blocked, and that the system is a minimum of one meter from a solid surface such as a wall or partition. Air flow through the 2Gb SANbloc Series is from front to rear. Mechanical Loading Consideration should be given to the loading of any equipment racks. To maintain a low centre of gravity (thus reducing the likelihood of instability) racks should be loaded (where possible) from the bottom of the equipment rack upwards. This is recommended to ensure personal safety. CAUTION: When installing or removing a rack mount enclosure, remove all disk drives. It is recommended that you work with at least one other person when installing an enclosure. This is necessary to prevent personal injury and damage to the enclosure. Installing the System in an Equipment Rack