Adaptec LSM-FC2002 Installation Guide - Page 45
Connecting a Power Source, Connecting an AC, Power Source
UPC - 760884145067
View all Adaptec LSM-FC2002 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
45 Connecting a Power Source The 2Gb SANbloc enclosure supports dual AC power supplies. Only one power supply is required for normal operation. However, a second, optional power supply may be added to provide a redundant power system. Each power supply has its own AC power inlet. CAUTION: Power supply cords shall have conductors with a cross-sectional area not less than 4mm2. This cross-sectional area corresponds to a minimum 10AWG wire. Connecting an AC Power Source 1 Ensure all cables have been attached as described in the preceding sections. 2 Attach the AC power cords to the power supplies and turn the power supply switches to the On (-) position (see Figure 3-5). Figure 3-5 Attaching the AC power cords 1 1 2 2 I 0 I 0 Insert Power cords into power connectors WARNING: This equipment must be connected to an earthed mains socket outlet. Ensure the power cabling provides earthing continuity to the equipment. Connecting a Power Source