Compaq DL580 Service Guide - Page 108
FYI: Drive bay, from SCSI Port
UPC - 720591733483
View all Compaq DL580 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 108 highlights
Diagnostics and Troubleshooting 3-39 Table 3-18 Array Diagnostic Utility (ADU) Error Messages continued Message Description Recommended Action Duplicate write memory error Data could not be written to the array accelerator board in duplicate due to the detection of parity errors. This is not a data loss situation. Replace the array accelerator board. Error occurred reading RIS copy from SCSI Port X Drive ID An error occurred while ADU was trying to read the reserve information sector (RIS) from this drive. Compaq stores the hard drive configuration information in the reserve information sector. If there were multiple errors, the drive may need to be replaced. FYI: Drive (bay) X is non-Compaq supplied Compaq did not supply the installed If problems exist with this drive, replace it with a drive. Compaq drive. Identify controller data did not match with NVRAM The controller identification data from the array controller did not match with the information stored in nonvolatile RAM. This could occur if new, previously configured drives have been placed in a system that has also been previously configured. It could also occur if the firmware on the controller has been upgraded and the server setup utility was not run. Run the INSPECT Utility to check the controller identification data. If the firmware version field is the only difference between the controller and nonvolatile RAM data, this is not a problem. Otherwise run the server setup utility. Identify logical drive data did not match with NVRAM The identify unit data from the array controller did not match with the information stored in nonvolatile RAM (NVRAM). This could occur if new, previously configured drives have been placed in a system that has also been previously configured. Run the server setup utility to configure the controller and nonvolatile RAM. Insufficient adapter resources The adapter does not have sufficient resources to perform posted-write operations to the array accelerator board. Drive rebuild may be occurring. Operate the system without the array accelerator board until the drive rebuild completes. Inter-controller link Unable to communicate over the connection could not link connecting the redundant be established controllers. Make sure both controllers are using the same hardware and firmware revisions. If one controller failed, replace it. Less than 75% batteries at sufficient voltage The operation of the array accelerator board has been disabled due to less than 75% of the battery packs being at the sufficient voltage level. Allow sufficient time for the batteries to recharge (36 hours). If the batteries have not recharged after 36 hours, replace the array accelerator board. Less than 75% of batteries at sufficient voltage Battery pack X below reference voltage Battery pack on the array accelerator is below the required voltage levels. Allow enough time for batteries to recharge (36 hours). If batteries have not recharged after 36 hours, replace the array accelerator board. continued