Compaq DL580 Service Guide - Page 121
EISA nonvolatile RAM., WARNING: Storage
UPC - 720591733483
View all Compaq DL580 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 121 highlights
3-52 Compaq ProLiant DL580 Server Maintenance and Service Guide Table 3-18 Array Diagnostic Utility (ADU) Error Messages continued Message Description Recommended Action WARNING: Storage enclosure on SCSI bus X indicated it is operating in single ended mode. One or more single-ended mode SCSI drives are installed in an external storage unit that operates in low voltage differential (LVD) mode. The array is operational, but installing all LVD drives maximizes performance. SOLUTION: This usually occurs when a single ended drive type is inserted into an enclosure with other drive types; and that makes the entire enclosure operate in single ended mode. To maximize performance replace the single ended mode drive with a type that matches the other drives. Write memory error Data could not be written to the cache memory. This typically means that a parity error was detected while writing data to the cache. This could be caused by an incomplete connection between the cache and the controller. This is not a data loss circumstance. With system powered down, verify that the cache board is fully connected to the controller. Wrong Accelerator This could mean that the board was replaced in the wrong slot or was placed in a system previously configured with another board type. Included with this message is a message indicating (1) the type of adapter sensed by ADU, and (2) the type of adapter last configured in EISA nonvolatile RAM. Check the diagnosis screen for other error messages. Run the server setup utility to update the system configuration.