3-42 Compaq ProLiant DL580 Server Maintenance and Service Guide Table 3-18 Array Diagnostic Utility (ADU) Error Messages continued Message Description Recommended Action Other controller indicates different cache size The other controller in the redundant controller configuration has a different size array accelerator. Make sure both controllers are using the same capacity array accelerator. RIS copies between drives do not match The drives on this controller contain copies of the RIS that do not match. The hard drives in the array do not have matching configuration information. To remedy: 1. Resolve all other errors encountered. 2. Obtain the latest version of ADU, and then rerun ADU. 3. If unconfigured drives were added, configure these drives using the Array Configuration Utility (ACU). Once these drives are configured, the error should be resolved. 4. If drives or arrays were moved, make sure the movement adheres to the guidelines listed in the documentation for the array controller. 5. If the error persists after completing steps 1-4, contact a Compaq authorized service provider. SCSI port X Drive ID Y failed - REPLACE (failure message) ADU detected a drive failure. Correct the condition that caused the error, if possible, or replace the drive. SCSI port X, Drive ID Y firmware needs upgrading Firmware for the drive may cause problems and should be upgraded. Run Options ROMPaq Utility to upgrade the drive's firmware to a later revision. SCSI port X, Drive ID Y has exceeded threshold(s) The monitor and performance threshold for this drive has been violated. Verify and resolve the threshold that has been violated. continued