Compaq DL580 Service Guide - Page 77

Table 3-2, POST Error Messages, Error Code, Audible Beeps, Probable Source of Problem

Page 77 highlights

3-8 Compaq ProLiant DL580 Server Maintenance and Service Guide Table 3-2 POST Error Messages Error Code A Critical Error occurred prior to this power up Unsupported Processor Detected System Halted Audible Beeps None 1 long, 1 short FATAL ROM ERROR: The System ROM is not properly programmed 101-ROM Error 1 long, 1 short 1 long, 1 short 101-I/O ROM Error None 102-System Board Failure 104-ASR-2 Timer Failure 105-Current System ROM is corrupt - now booting redundant System ROM 162-System Options Not Set 163-Time & Date Not Set 164-Memory Size Error 172-Configuration Nonvolatile Memory Invalid 173-Slot ID Mismatch 174-Configuration/ Slot Mismatch Device Not Found 175-Configuration/ Slot Mismatch Device Found None None 2 long 2 short 2 short 2 short None None None None Probable Source of Problem A catastrophic system error, which caused the server to crash, has been logged. Processor not supported by current system ROM ROM incorrectly programmed in factory Recommended Action Run Diagnostics. Replace failed assembly as indicated. Check documentation for supported processors, and if supported, remove the processor and update the system to latest ROM. Replace the physical ROM part. System ROM checksum Options ROM checksum DMA, timers System board failure Nonbooted ROM image is corrupt Run Diagnostics, then replace failed assembly as indicated. Run Diagnostics, then replace failed assembly as indicated. Replace the system board. Run the System Configuration Utility. Run Diagnostics. Replace failed assembly as indicated. Flash the ROM utilizing ROMPaq. Configuration incorrect Invalid time or date in configuration memory Configuration memory incorrect Nonvolatile configuration corrupt or jumper installed Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Board replaced, configuration not updated EISA or PCI board not found Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. EISA or PCI board added, configuration not updated Run the System Configuration Utility and correct. continued

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193

3-8
Compaq ProLiant DL580 Server Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code
Audible Beeps
Probable Source of Problem
Recommended Action
A Critical Error
occurred prior to this
power up
None
A catastrophic system error,
which caused the server to
crash, has been logged.
Run Diagnostics. Replace failed
assembly as indicated.
Unsupported
Processor Detected
System Halted
1 long, 1 short
Processor not supported by
current system ROM
Check documentation for
supported processors, and if
supported, remove the
processor and update the
system to latest ROM.
FATAL ROM ERROR:
The System ROM is
not properly
programmed
1 long, 1 short
ROM incorrectly programmed
in factory
Replace the physical ROM part.
101-ROM Error
1 long, 1 short
System ROM checksum
Run Diagnostics, then replace
failed assembly as indicated.
101-I/O ROM Error
None
Options ROM checksum
Run Diagnostics, then replace
failed assembly as indicated.
102-System Board
Failure
None
DMA, timers
Replace the system board. Run
the System Configuration Utility.
104-ASR-2 Timer
Failure
None
System board failure
Run Diagnostics. Replace failed
assembly as indicated.
105-Current System
ROM is corrupt
now booting
redundant System
ROM
2 long
Nonbooted ROM image is corrupt
Flash the ROM utilizing
ROMPaq.
162-System Options
Not Set
2 short
Configuration incorrect
Run the System Configuration
Utility and correct.
163-Time & Date Not
Set
2 short
Invalid time or date in
configuration memory
Run the System Configuration
Utility and correct.
164-Memory Size
Error
2 short
Configuration memory incorrect
Run the System Configuration
Utility and correct.
172-Configuration
Nonvolatile Memory
Invalid
None
Nonvolatile configuration corrupt
or jumper installed
Run the System Configuration
Utility and correct.
173-Slot ID
Mismatch
None
Board replaced, configuration not
updated
Run the System Configuration
Utility and correct.
174-Configuration/
Slot Mismatch Device
Not Found
None
EISA or PCI board not found
Run the System Configuration
Utility and correct.
175-Configuration/
Slot Mismatch Device
Found
None
EISA or PCI board added,
configuration not updated
Run the System Configuration
Utility and correct.
continued