Table 3-23, ASR-2 IML or Critical Error Log Messages, Message, Description
UPC - 720591733483
View all Compaq DL580 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 138 highlights
Diagnostics and Troubleshooting 3-69 Table 3-23 ASR-2 IML or Critical Error Log Messages continued Message Description Battery Failing Low system battery warning. Replace battery within 7 days to prevent loss of nonvolatile configuration memory. Failure of the battery supporting the system nonvolatile RAM is imminent. Caution: Temperature Exceeded The operating system detected that the temperature of the system exceeded the caution level. Accompanying data in the log notes if an auto-shutdown sequence was invoked by the operating system. Diagnostic Error An error was detected by the Diagnostics Utility. See the specific error code in this chapter for a detailed explanation. Error Detected On Boot Up The server detected an error during the Power-On Self-Test (POST). NMI - Automatic Server Recovery Timer Expiration The operating system received notice of an impending ASR-2 timer expiration. NMI - Expansion Board Error A board on the expansion bus indicated an error condition, resulting in a server failure. NMI - Expansion Bus Master Timeout A bus master expansion board in the indicated slot did not release the bus after its maximum time, resulting in a server failure. NMI - Expansion Bus Slave Timeout A board on the expansion bus delayed a bus cycle beyond the maximum time, resulting in a server failure. NMI - Fail-Safe Timer Expiration Software was unable to reset the system fail-safe timer, resulting in a server failure. NMI - PCI Bus Parity Error A parity error was detected on the PCI bus. NMI - Processor Parity Error The processor detected a data error, resulting in a server failure. NMI - Software Generated Interrupt Detected Error Software indicated a system error, resulting in a server failure. Processor Exception The indicated processor exception occurred. Processor Prefailure A CPU passed an internal corrected error threshold; excessive internal ECC cache errors. Required System Fan Failure The required system fan failed. Accompanying data in the log notes if an auto-shutdown sequence was invoked by the operating system. Server Manager Failure An error occurred with the Server Manager/R board. UPS AC Line Failure Shutdown or Battery Low The UPS notified the operating system that the AC power line failed. Accompanying data indicates an auto-shutdown sequence was invoked or the battery was nearly depleted.