Port bit 5 not at zero
View all Compaq Portable 286 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
102 - 08 287 Coprocessor wrong mask bit set in status register 102 - 15 287 socket is unoccupied, or 287 is inoperative Error Error Required Code Description Action 103 - 01 8237 DMA page registers Replace the system board for error test codes 103 - 01 through 113 - 01. 103 - 02 8237 DMA byte controller test failed 103 - 03 8237 DMA word controller test failed 104 - 01 8259 interrupt controller master test failed 104 - 02 8259 interrupt controller slave test failed 104 - 03 8259 software RTC is inoperative 105 - 01 Port bit 6 not at zero 105 - 02 Port bit 5 not at zero 105 - 03 Port bit 3 not at zero 105 - 04 Port bit 1 not at zero 105 - 05 Port bit 0 not at zero 105 - 06 Port bit 5 not at one 105 - 07 Port bit 3 not at one 105 - 08 Port bit 1 not at one 105 - 09 Port bit 0 not at one Error Error Required Code Description Action Processor 1yy - xx 106 - 01 8042 keyboard controller Replace the system board for error self test failed codes 103 - 01 through 113 - 01. 107 - 01 CMOS RAM test failed 108 - 02 CMOS interrupt test failed