Serial Clock Test, data, Fixed Disk Drive
View all Compaq Portable 286 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
line failure 1109 - 06 Serial Clock Test, data line failure Error Error Required Code Description Action Fixed Disk Drive 17yy - xx 1700 - xx Fixed disk drive ID drive The following steps apply to error test type codes 1700 - xx through 1716 - 59: 1701 - xx 1702 - xx 1703 - xx 1704 - xx 1705 - xx 1706 - xx Fixed disk drive format test Fixed disk drive read test Fixed disk drive write/ read/compare test Fixed disk drive random seek test Fixed disk drive controller test Fixed disk drive ready test 1. Check the fixed disk drive controller board for the proper switch setting (see Chapter 8). * 2. Replace the fixed disk drive signal and power cables. 3. Replace the fixed disk drive controller board. * 4. Replace the fixed disk drive assembly. 5. Replace the system board. * 286 based COMPAQ Personal Computers only 1707 - xx Fixed disk drive recalibrate test 1708 - xx Fixed disk drive format bad track test 1709 - xx Fixed disk drive reset controller test 1710 - xx Fixed disk drive park head test 1714 - xx Fixed disk drive file write test Error Error Required Code Description Action Fixed Disk Drive 17yy - xx 1715 - xx Fixed disk drive head select The following steps apply to error test codes 1700 - xx through 1716 - 59: 1716 - xx 1716 - 01 Fixed disk drive conditional format test Exceeded maximum soft error limit 1. Check the fixed disk drive controller board for the proper switch setting (see Chapter 8). * 2. Replace the fixed disk drive signal and power cables.