Dell PowerEdge R440 EMC Installation and Service Manual 1 - Page 87

Internal PERC riser, Removing the internal PERC riser

Page 87 highlights

• Ensure that the pin 1 indicator on the heat sink is aligned with the pin 1 indicator on the bracket before placing the heat sink onto the processor and bracket. Figure 48. Installing the heat sink onto the processor Next steps 1. Install the processor and heat sink module. 2. Install the air shroud. 3. Follow the procedure listed in After working inside your system. Internal PERC riser Removing the internal PERC riser Prerequisites 1. Follow the safety guidelines listed in Safety instructions. 2. Follow the procedure listed in Before working inside your system. 3. Remove the air shroud. Steps 1. Open the cable guiding latch for easy access. 2. Lower the plunger. 3. Press the cable connector and disconnect the PERC cable from the backplane. 4. Hold the blue touch points and lift the internal PERC riser out of the system. Installing and removing system components 87

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141

Ensure that the pin 1 indicator on the heat sink is aligned with the pin 1 indicator on the bracket before placing
the heat sink onto the processor and bracket.
Figure 48. Installing the heat sink onto the processor
Next steps
1.
Install the processor and heat sink module.
2.
Install the air shroud.
3.
Follow the procedure listed in
After working inside your system
.
Internal PERC riser
Removing the internal PERC riser
Prerequisites
1.
Follow the safety guidelines listed in
Safety instructions
.
2.
Follow the procedure listed in
Before working inside your system
.
3.
Remove the air shroud.
Steps
1.
Open the cable guiding latch for easy access.
2.
Lower the plunger.
3.
Press the cable connector and disconnect the PERC cable from the backplane.
4.
Hold the blue touch points and lift the internal PERC riser out of the system.
Installing and removing system components
87