Dell PowerVault NX200 Hardware Owner's Manual - Page 25
continued, E122C CPU Power
View all Dell PowerVault NX200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Table 1-1. LCD Status Messages (continued) Code Text Causes Corrective Actions E1229 CPU # VCORE Regulator failure. Reseat CPU. Specified processor VCORE voltage regulator has failed. Reseat the processor. See "Troubleshooting the Processor" on page 144. If the problem persists, see "Getting Help" on page 157. E122A CPU # VTT Regulator failure. Reseat CPU. Specified processor VTT Reseat the processor. voltage regulator has failed. See "Troubleshooting the Processor" on page 144. If the problem persists, see "Getting Help" on page 157. E122C CPU Power A power fault was Fault. Power detected when powering cycle AC. up the processor. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 157. E122D Memory One of the memory Regulator # regulators has failed. Failed. Reseat DIMMs. Reseat the memory modules. See "Troubleshooting System Memory" on page 137. E122E On-board regulator failed. Call support. One of the on-board voltage regulators failed. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 157. E1310 Fan ## RPM exceeding range. Check fan. RPM of fan is outside of the intended operating range. See "Troubleshooting System Cooling Problems" on page 136. About Your System 25