Dell PowerVault NX200 Hardware Owner's Manual - Page 28
E1710 I/O channel, Check PSU - review
View all Dell PowerVault NX200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Table 1-1. LCD Status Messages (continued) Code Text Causes Corrective Actions E1620 Power Supply # (### W) AC power error. Check PSU cables. Specified power supply's AC input is outside of the allowable range. Check the AC power source for the specified power supply. If the problem persists, see "Troubleshooting the Power Supply" on page 135. E1629 Power The system configuration Turn off power to the required > requires more power system, reduce the PSU wattage. than the power supply can hardware configuration or Check PSU and provide, even with install higher-wattage config. throttling. power supply, and then restart the system. E1710 I/O channel check error. Review & clear SEL. The system BIOS has reported an I/O channel check. Check the SEL for more information and then clear the SEL. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 157. E1711 PCI parity error on Bus ## Device ## Function ## The system BIOS has Remove and reseat the reported a PCI parity error PCIe expansion cards. on a component that If the problem persists, resides in PCI see "Troubleshooting configuration space at Expansion Cards" on bus ##, device ##, page 143. function ##. PCI parity The system BIOS has Remove and reseat the error on Slot reported a PCI parity error PCIe expansion cards. #. Review & on a component that If the problem persists, clear SEL. resides in the specified slot. see "Troubleshooting Expansion Cards" on page 143. 28 About Your System