Epson TM-H6000IV with Validation Technical Reference Guide - Page 46
For Serial Interface, DIP Switch Bank 1
![]() |
View all Epson TM-H6000IV with Validation manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
For Serial Interface DIP Switch Bank 1 SW Function ON OFF Initial setting 1-1 Data reception error Ignored Prints "?" OFF 1-2 Receive buffer capacity 45 bytes 4 KB OFF 1-3 Handshaking XON/XOFF DTR/DSR OFF 1-4 Word length 7 bits 8 bits OFF 1-5 Parity check Yes No OFF 1-6 Parity selection Even Odd OFF 1-7 See the " Transmission Speed (DIP Switches ON Transmission speed selections 1-8 1-7/1-8)" table below. OFF Transmission Speed (DIP Switches 1-7/1-8) Transmission speed (bps: bits per second) 4800 9600 19200 (initial setting) Setting with the memory switch*: 2400, 4800, 9600, 19200, 38400 (initial setting), 57600, 115200 SW 1-7 ON OFF ON OFF SW 1-8 ON ON OFF OFF bps: bits per second * When DIP switches 1-7 and 1-8 are set to OFF, the value (initially 38400) can be set to any of the values listed in the lower portion of the row using a command, memory switch setting mode, or the TM-H6000IV Utility. (See "Setting the Memory Switches/Receipt Enhancement" on page 65.) Depending on print conditions, such as print duty, print head temperature, and data transmission speed, print speed is automatically adjusted, which can cause white lines due to intermittent print (the motor sometimes stops). To avoid this, set the transmission speed higher or keep the print speed constant by setting it lower. (See "Setting the Memory Switches/Receipt Enhancement" on page 65.) 46
![](/manual_guide/products/epson-tmh6000iv-validation-technical-reference-guide-53ccca5/46.png)