Epson tmu375 User Manual - Page 31

TM-U375 DIP-switch functions, DIP Switch Set 1 - error

Page 31 highlights

TM-U375 DIP-switch functions DIP Switch Set 1 SW Function l-1 Data reception error l-2 Receive buffer capacity l-3 Handshaking l-4 Word length 1-5 Parity check l-6 Parity selection l-7 Transfer speed (see table below) l-8 Transfer speed (see table below) ON Ignored 40 bytes XON/XOFF 7 bits Yes Even OFF Prints ' ? ' 4K bytes DTR/DSR 8 bits No Odd Transfer Speed (BPS) 1200 2400 4800 9600 BPS: Bits Per Second SW7 ON OFF ON OFF SW8 ON ON OFF OFF DSW2 SW Function ON OFF 2-l Connection of display module Connected Not connected (see Note 1 on the next page) 2-2 Selects number of characters 42 CPL/ 40 CPU per line (CPL) 35 CPL 33 CPL 7 X 9 font/5 X 9 font (refer to the Notes on Number of Printable Columns section in Chapter 4) 2-3 Handshaking operation (busy condition) 2-4 For internal use only. 2-5 For internal use only. 2-6 For internal use only. 2-7 Pin 6 reset signal (see Note 2 on the next page) 2-8 Pin 25 reset signal (see Note 2 on the next page) Receive buffer full Off-line or receive buffer full Used Used Not used Not used Do not change the settings of switch 2-4, 2-5 and 2-6. Setting Up the Printer 1-21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

TM-U375 DIP-switch functions
DIP Switch Set 1
SW Function
l-1 Data reception error
ON
OFF
Ignored
Prints
'
?
'
l-2
Receive buffer capacity
l-3
Handshaking
l-4
Word length
1-5
Parity check
l-6
Parity selection
l-7
Transfer speed (see table below)
40
bytes
4K
bytes
XON/XOFF
DTR/DSR
7 bits
8 bits
Yes
No
Even
Odd
l-8
Transfer speed (see table below)
Transfer Speed (BPS)
1200
2400
4800
9600
BPS: Bits Per Second
SW7
SW8
ON
ON
OFF
ON
ON
OFF
OFF
OFF
DSW2
SW
Function
2-l
Connection of display module
ON
OFF
Connected
Not connected
2-2
2-3
2-4
2-5
2-6
2-7
2-8
(see Note
1
on the next page)
Selects number of characters
42
CPL/
40 CPU
per line
(CPL)
35
CPL
33
CPL
7
X
9 font/5
X
9 font
(refer to the
Notes on Number
of
Printable Columns
section in Chapter
4)
Handshaking operation
(busy condition)
For internal use only.
For internal use only.
For internal use only.
Pin 6 reset signal
(see Note 2 on the next page)
Pin 25 reset signal
(see Note 2 on the next page)
Receive
Off-line or
buffer full
receive buffer full
Used
Not used
Used
Not used
Do
not
change
the
settings
of
switch
2-4, 2-5
and
2-6.
Setting Up the Printer
1-21