Fujitsu MHT2030AT Manual/User Guide - Page 116
X'XX' Current set value., Performance mode
UPC - 683728090579
View all Fujitsu MHT2030AT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 116 highlights
Interface '00' = Reserved '01' = Using a jumper. '10' = Using the CSEL signal. '11' = Other method. Bit 8: = '1' (In the case of device 1) Bits 7-0: In the case of Device 0 (master drive), a valid value is set. Bit 7: Reserved Bit 6: '1' = Device 1 is selected, Device 0 responds. Bit 5: '1' = Device 0, assertion of DASP- was detected. Bit 4: '1' = Device 0, assertion of PDIAG- was detected. Bit 3: '1' = Device 0, an error was not detected in the selfdiagnosis. Bit 2, 1: Method for deciding the device No. of Device 0. '00' = Reserved '01' = Using a jumper. '10' = Using the CSEL signal. '11' = Other method. Bit 0: '1'= (In the case of device 0) *21 WORD 94 Bit 15-8: X'FE' Recommended acoustic management value. Bit 7-0: X'XX' Current set value. FE-C0: Performance mode BF-80: Acoustic mode 00: Acoustic management is unused it. (It is same as "FE-CO") *22 WORD 100-103 When "48 bit LBA" of the option (customize) is supported, same number of LBA as WORD 60-61 is displayed. *23 WORD 128 Bit 15-9: Reserved Bit 8: Security level. 0: High, 1: Maximum Bit 7-6: Reserved 5-42 C141-E192-02EN