Fujitsu MHT2030AT Manual/User Guide - Page 152
Pointer for the latest Error Log Data Structure, Table 5.11, Data format of SMART Summary Error Log
UPC - 683728090579
View all Fujitsu MHT2030AT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 152 highlights
Interface Table 5.11 Data format of SMART Summary Error Log Byte Item 00 Version of this function 01 Pointer for the latest "Error Log Data Structure" 02 to 31 32 33 Error log data structure Reserved Command data structure Device Control register value Features register value 34 Sector Count register value 35 Sector Number register value 36 Cylinder Low register value 37 Cylinder High register value 38 Drive/Head register value 39 Command register value 3A to 3D Elapsed time after the power-on sequence (unit: ms) 3E Error data Reserved 3F structure Error register value 40 Sector Count register value 41 Sector Number register value 42 Cylinder Low register value 43 Cylinder High register value 44 Drive/Head register value 45 Status register value 46 to 58 Vendor unique 59 State 5A, 5B Power-on time (unit: h) 5C to 1C3 Error log data structure 2 to Error log data structure 5 Format of each error log data structure is same as those of bytes 02 to 5B. 1C4, 1C5 Number of unrecoverable errors that have occurred. 1C6 to 1FE Reserved 1FF Check sum 5-78 C141-E192-02EN