Diagnostics 1. Press the Menu button until the Diagnostic screen appears (fig 83). This menu provides important information about the performance of the pump that can be used during troubleshooting. Below are the different screens and their meaning. These are all real-time displays. Press the „>‟ button to view information. Serial Number 03045433 Drive Rev: 2.2 Display Rev: 1.16 Product Version SP3400VSP Input Voltage Within Range Motor Current 1.1A (0-13.0A) Displays firmware of both drive and display. Also shows "too high" or "too low" Current range shown in ( ) Power Usage 225W (0-2650W) Figure 83 Power usage range shown in ( ) Driver: 78C Heatsink: 67C Com Bus Online (addr: 1) Temperature of heatsink and drive. Status of com link between VSC and Hayward control. Reads offline when not connected Event Log Press + to View By pressing the + button you will see the last 20 error and or trip conditions, as well as the amount of time that has elapsed since the condition occurred. Page 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

Diagnostics
1.
Press the Menu button until the Diagnostic screen
appears
(fig 83).
This menu provides important
information about the performance of the pump that can
be used during troubleshooting.
Below are the different
screens and their meaning.
These are all real-time
displays.
Press the „
>‟
button to view information.
Serial Number
03045433
Drive Rev:
2.2
Display Rev:
1.16
Input Voltage
Within Range
Motor Current
1.1A
(0-13.0A)
Power Usage
225W (0-2650W)
Product Version
SP3400VSP
Driver:
78C
Heatsink:
67C
Com Bus
Online (addr: 1)
Event Log
Press + to View
Displays firmware of
both drive and display.
Also shows “too
high” or “too low”
Current range shown
in (
)
Power usage range
shown in (
)
Temperature of
heatsink and drive.
Status of com link between
VSC and Hayward control.
Reads offline when not
connected
By pressing the + button you will see the last 20
error and or trip conditions, as well as the amount of
time that has elapsed since the condition occurred.
Page 41
Figure 83