Hayward Variable Speed Pump Technical Guide - Page 49
GL/Hayward control. - error code 20
View all Hayward Variable Speed Pump manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
Troubleshooting/Fault Codes Code/Fault Indications EcoStar is connected and configured to operate with a GL/Hayward control. The pump comes on in Standalone mode. Control reads "Pool bridge comm." Check comm. wires between GL/Hayward control and EcoStar. Be sure they are on the EcoStar comm. bus connection and NOT the input connections for relay control (page 10) . Be sure EcoStar is configured for Standalone/Hayward. . The EcoStar should be wired to a dedicated 15 amp double pole breaker. No connections are made to the line or load side of the filter pump relay in the control (page 5). EcoStar is connected and operating via GL/Hayward control. The %/rpm reading does not match between the pump interface and the control Check to make sure the Min and Max setting on the EcoStar is set at the minimum (600rpm/17%) and the maximum (3450rpm/100%) so as to not interfere with the settings in the control (page 20) EcoStar reverts to Standalone mode even when properly connected to the GL/Hayward control. No error on control display. Check the settings in the control filter configuration menu and set to variable speed . Page 47