HP Integrity Superdome 2 8/16 HP Smart Update Manager 5.0 User Guide - Page 38

Component configuration for Windows components only, Command-line examples

Page 38 highlights

Command /use_ams/use_wmi /use_wmi/use_snmp G7 and earlier WBEM and SNMP WBEM and SNMP /use_ams/use_wmi/us WBEM and SNMP e_snmp The following table shows what updates if WBEM switches are currently installed: Command G7 and earlier no switches /use_ams /use_snmp /use_wmi /use_ams/use_snmp /use_ams/use_wmi /use_wmi/use_snmp WBEM WBEM WBEM and SNMP WBEM WBEM and SNMP WBEM WBEM and SNMP /use_ams/use_wmi/us WBEM and SNMP e_snmp Component configuration for Windows components only To configure components without using the HP Smart Update Manager GUI, issue the command, hpsum_config . This command presents the same configuration screens seen in the HP Smart Update Manager GUI. You must run this command from a CD or other read-only media, or the component cannot be configured. Configuration for a given component only needs to be executed one time. The configuration is stored within the component and is propagated to all target servers when deployed through HP Smart Update Manager GUI or command line. To change the configuration, rerun hpsum_config against the component and a new configuration writes out. If a component does not need configuration, the hpsum_config command returns to the console. To configure components to be deployed on all editions of the Windows Server® 2008 with the Server Core option, you must access the system as a remote host using HP Smart Update Manager running on a system with a supported Windows® operating system, and then configure the components before deployment. Command-line examples The following command-line parameter examples can be executed within these environments: • Firmware: o System ROM o Smart Array controller o Hard drives o iLO • Software-later version of: o HP Insight Diagnostics Online Edition for Windows Server 2003 (cp008097.exe) Scripted deployment 38

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

Scripted deployment 38
Command
G7 and earlier
/use_ams/use_wmi
WBEM and SNMP
/use_wmi/use_snmp
WBEM and SNMP
/use_ams/use_wmi/us
e_snmp
WBEM and SNMP
The following table shows what updates if WBEM switches are currently installed:
Command
G7 and earlier
no switches
WBEM
/use_ams
WBEM
/use_snmp
WBEM and SNMP
/use_wmi
WBEM
/use_ams/use_snmp
WBEM and SNMP
/use_ams/use_wmi
WBEM
/use_wmi/use_snmp
WBEM and SNMP
/use_ams/use_wmi/us
e_snmp
WBEM and SNMP
Component configuration for Windows components only
To configure components without using the HP Smart Update Manager GUI, issue the command,
hpsum_config
<component_to_configure>.
This command presents the same configuration screens seen
in the HP Smart Update Manager GUI. You must run this command from a CD or other read-only media, or
the component cannot be configured. Configuration for a given component only needs to be executed one
time. The configuration is stored within the component and is propagated to all target servers when deployed
through HP Smart Update Manager GUI or command line. To change the configuration, rerun
hpsum_config
against the component and a new configuration writes out. If a component does not need
configuration, the
hpsum_config
command returns to the console.
To configure components to be deployed on all editions of the Windows Server® 2008 with the Server Core
option, you must access the system as a remote host using HP Smart Update Manager running on a system
with a supported Windows® operating system, and then configure the components before deployment.
Command-line examples
The following command-line parameter examples can be executed within these environments:
Firmware:
o
System ROM
o
Smart Array controller
o
Hard drives
o
iLO
Software—later version of:
o
HP Insight Diagnostics Online Edition for Windows Server 2003 (
cp008097.exe
)