HP Integrity Superdome SX2000 HP Integrity Servers with Microsoft Windows Serv - Page 22

Fibre Channel

Page 22 highlights

• Unset the Administrator password. • Run EBSU from the EFI Shell instead of from the EFI Boot Manager. The EFI Shell can unblock the MPS Setting. EBSU fails when flashing an Emulex 4 Gb HBA Issue Servers Workaround EBSU cannot flash the Emulex 4 Gb Host Bus Adapter (HBA) to the latest firmware and EFI version, if the current EFI Driver flashed to the Emulex 4 Gb controller is version 5.02A1. All Integrity 1. Exit EBSU. 2. Unload all Emulex drivers using the EFI shell unload command. 3. Run EBSU again. ESBU can lose mapping of drives connected to QLogic controllers Issue Servers Workaround In some cases, EBSU may lose the mapping of disk drives attached to Qlogic controllers. All Integrity Use "Maintain Firmware" to flash the QLogic controller to the latest firmware. After reboot the system, EBSU detects and configures the disk drives attached to the QLogic controller. Express Setup fails when launched from EBSU Issue Servers Workaround The OS installer fails when launched by EBSU if the DVD drive is attached to a U320 controller. All Integrity 1. Exit EBSU. 2. Put the OS media in the DVD drive. 3. From the EFI Shell, issue the reconnect -r command followed by the map -r command. 4. Run the OS installer. Fibre Channel Installation causes MSA 1500 driver to be flagged Issue Servers Workaround A yellow exclamation mark (!) might be displayed for the HP StorageWorks 1000/MSA 1500 event notification driver after installing the Windows Server 2003 SP2 operating system using the 5.2 release reinstall media. All Integrity Using the Release 5.2 HP Smart Setup Media (SSM) CD, do one of the following: • Install the Support Pack (recommended). • Install HP StorageWorks MSA1000/MSA1500 Event Notification Driver component. Target LUN and boot controller WWN not visible in a VC environment Issue Servers When installing to storage attached to an Emulex LPe1105 mezzanine controller (403621-B21) in a Virtual Connect (VC) environment through a Brocade switch, the target LUN is not visible and the WWN for the boot controller is not visible in the zone in the switch administrative tool. HP Integrity BL860c Server Blade and BL870c Server Blade 22 Release 6.1 Overview

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

Unset the Administrator password.
Run EBSU from the EFI Shell instead of from the EFI Boot Manager. The
EFI Shell can unblock the MPS Setting.
EBSU fails when flashing an Emulex 4 Gb HBA
Issue
EBSU cannot flash the Emulex 4 Gb Host Bus Adapter (HBA) to the latest
firmware and EFI version, if the current EFI Driver flashed to the Emulex 4 Gb
controller is version 5.02A1.
Servers
All Integrity
Workaround
Exit EBSU.
1.
2.
Unload all Emulex drivers using the EFI shell
unload
command.
3.
Run EBSU again.
ESBU can lose mapping of drives connected to QLogic controllers
Issue
In some cases, EBSU may lose the mapping of disk drives attached to Qlogic
controllers.
Servers
All Integrity
Workaround
Use "Maintain Firmware" to flash the QLogic controller to the latest firmware.
After reboot the system, EBSU detects and configures the disk drives attached
to the QLogic controller.
Express Setup fails when launched from EBSU
Issue
The OS installer fails when launched by EBSU if the DVD drive is attached to
a U320 controller.
Servers
All Integrity
Workaround
Exit EBSU.
1.
2.
Put the OS media in the DVD drive.
3.
From the EFI Shell, issue the
reconnect -r
command followed by the
map -r
command.
4.
Run the OS installer.
Fibre Channel
Installation causes MSA 1500 driver to be flagged
Issue
A yellow exclamation mark (
!
) might be displayed for the HP StorageWorks
1000/MSA 1500 event notification driver after installing the Windows Server
2003 SP2 operating system using the 5.2 release reinstall media.
Servers
All Integrity
Workaround
Using the Release 5.2 HP Smart Setup Media (SSM) CD, do one of the following:
Install the Support Pack (recommended).
Install HP StorageWorks MSA1000/MSA1500 Event Notification Driver
component.
Target LUN and boot controller WWN not visible in a VC environment
Issue
When installing to storage attached to an Emulex LPe1105 mezzanine controller
(403621-B21) in a Virtual Connect (VC) environment through a Brocade switch,
the target LUN is not visible and the WWN for the boot controller is not visible
in the zone in the switch administrative tool.
Servers
HP Integrity BL860c Server Blade and BL870c Server Blade
22