HP Integrity Superdome SX2000 HP Integrity Servers with Microsoft Windows Serv - Page 36

vKVM and vMedia

Page 36 highlights

vKVM and vMedia Tool bar fails to redraw as expected Issue Servers Workaround The vKVM window tool bar sometimes fails to redraw completely after other windows have been open on the screen. rx6600, rx3600, rx2660 Move the mouse to the toolbar area, and the tool bar becomes visible. vMedia drive not immediately accessible Issue Servers Workaround When using vMedia to connect client media (physical of ISO) to RUSA, there might be a delay before that vMedia drive is accessible from File Explorer on the RUSA system. This delay is typically a few minutes. rx6600, rx3600, rx2660 There is no workaround at this time. vKVM session stops updating Issue Servers Workaround The vKVM session stops updating in the middle of a Windows install from the Microsoft media when a monitor is connected to the VGA port of the server. rx6600, rx3600 Perform the installation from the Microsoft media without the monitor connected. This issue can be prevented by ensuring that the server vBIOS version is BK-ATI VER008.004.037.101. 36 Release 6.1 Overview

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

vKVM and vMedia
Tool bar fails to redraw as expected
Issue
The vKVM window tool bar sometimes fails to redraw completely after other
windows have been open on the screen.
Servers
rx6600, rx3600, rx2660
Workaround
Move the mouse to the toolbar area, and the tool bar becomes visible.
vMedia drive not immediately accessible
Issue
When using vMedia to connect client media (physical of ISO) to RUSA, there
might be a delay before that vMedia drive is accessible from File Explorer on
the RUSA system. This delay is typically a few minutes.
Servers
rx6600, rx3600, rx2660
Workaround
There is no workaround at this time.
vKVM session stops updating
Issue
The vKVM session stops updating in the middle of a Windows install from the
Microsoft media when a monitor is connected to the VGA port of the server.
Servers
rx6600, rx3600
Workaround
Perform the installation from the Microsoft media without the monitor
connected. This issue can be prevented by ensuring that the server vBIOS version
is BK-ATI VER008.004.037.101.
36
Release 6.1 Overview