HP LH4r HP Netserver LH 4 User Guide - Page 80

Symbios Configuration Utility

Page 80 highlights

Chapter 10 Configuring the NetServer • Include SCSI_A Channel [Yes/No] If the integrated HP NetRAID controller is enabled, this setting selectively includes or excludes SCSI port A from the HP NetRAID subsystem. • Include SCSI_B Channel [Yes/No] If the integrated HP NetRAID controller is enabled, this setting selectively includes or excludes SCSI port B from the HP NetRAID subsystem. NOTE If you enable HP NetRAID for just one SCSI channel, that becomes the integrated HP NetRAID Channel 0. If you enable both SCSI channels, SCSI A becomes Channel 0, and SCSI B becomes Channel 1. For single-channel RAID operation, HP recommends SCSI A. 5. If necessary, you can use the Setup utility to change other settings, such as IRQs or MP specification settings, or boot order. 6. Press the F10 function key to save and exit. 7. In the Setup Configuration dialog box, press the Enter key to answer "yes" to the question: "Save configuration and exit now?" The NetServer will reboot. For complete information on HP NetRAID, see the Integrated HP NetRAID Configuration Guide. Symbios Configuration Utility If you need to verify or modify SCSI host adapter settings, or if you need to lowlevel format SCSI disks or verify SCSI disk media, run the Symbios Configuration utility, as follows: Turn on or reboot your system. During system start-up or reset, when the message Press to start Symbios Configuration Utility appears, press the CTRL and C keys at the same time. 74

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126

Chapter 10
Configuring the NetServer
74
Include SCSI_A Channel [Yes/No]
If the integrated HP NetRAID controller is enabled, this
setting selectively includes or excludes SCSI port A from the
HP NetRAID subsystem.
Include SCSI_B Channel
[Yes/No]
If the integrated HP NetRAID controller is enabled, this
setting selectively includes or excludes SCSI port B from the
HP NetRAID subsystem.
NOTE
If you enable HP NetRAID for just one SCSI channel, that
becomes the integrated HP NetRAID Channel 0. If you enable
both SCSI channels, SCSI A becomes Channel 0, and SCSI B
becomes Channel 1. For single-channel RAID operation, HP
recommends SCSI A.
5.
If
necessary, you can use the Setup utility to change other settings,
such as IRQs or MP specification settings, or boot order.
6.
Press the
F10
function key to save and exit.
7.
In the Setup Configuration dialog box, press the Enter key to answer
"yes" to the question: "Save configuration and exit now?" The
NetServer will reboot.
For complete information on HP NetRAID, see the
Integrated HP NetRAID
Configuration Guide.
Symbios Configuration Utility
If you need to verify or modify SCSI host adapter settings, or if you need to low-
level format SCSI disks or verify SCSI disk media, run the Symbios
Configuration utility, as follows:
Turn on or reboot your system.
During system start-up or reset, when the message
Press <Ctrl> <C> to start Symbios Configuration
Utility
appears, press the CTRL and C keys at the same time.