Choose one of the valid drive types: [SCSI | SAS | SATA | SATASSD | SASSSD] The value is often used with the wildcard (*) or number argument for Drive. Join To use the Join command, observe the following requirements: • The system must be offline. • The -offline command line flag must be set when you start ACU Scripting. The command fails if the OS reports that any of the volumes involved in the join are in use. CAUTION: Executing the Join command on an online system can result in kernel panics, blue screens, and/or data loss. The Split command converts a RAID 1 or RAID 10 logical volume into two RAID 0 logical volumes. The Join option reverses the splitting process by recombining the two RAID 0 volumes into a single RAID 1 or RAID 10 volume, depending on the number of physical disks. For this process, ID is the ID of the resulting volume that was joined. All data on the other volume is lost. Array = C Join = A After the command executes, Array C is removed, and its physical drives are now a mirror of the drives in Array A. The original contents of Array C are lost. OnlineSpare The value for this option determines whether the array specified previously in the script will be configured with spare drives. The interface type for drives and spare drives must match, for example, all SAS or all SATA. Method mode Custom Auto Possible values Default value To specify exactly which drives to use as spares, In Configure action mode: None use the applicable convention (port:ID, box:bay, In Reconfigure action mode, ACU or port:box:bay). ignores any value entered for this To specify only the number of spares (not the option and keeps any spares that are exact IDs), enter that number as the value for this already present in the configuration. option. ACU automatically selects only those drives that are suitable for the array. To specify that the array should not have spares, enter None. Yes (indicating one spare) In Configure action mode: Yes No (indicating one spare) In Reconfigure action mode, ACU ignores any value entered for this option and keeps any spares that are already present in the configuration. Split This command splits RAID 1 or RAID 10 volumes into individual RAID 0 volumes. Two values are available: HP Array Configuration Utility 82