HP ProLiant DL380p Configuring Arrays on HP Smart Array Controllers Reference - Page 91

ACU scripting warning messages, <!ELEMENT Initiator HBA_WW_ID, ConnectionName?, HostMode? &gt

Page 91 highlights

]> ACU scripting warning messages Warning code 4000 4001 4002 4003 4004 4005 4006 Warning message Comment or clarification License key is already installed The input file specified a license key. However, a license key is already installed on the controller. Clear configuration command failed configuration is already cleared The -reset option was used on a controller that does not have a configuration. Chassis name is already set to this value The chassis name is already set to the supplied value. The command is ignored. One or more controller commands were skipped because the controller is not configured Using Repeat function Certain commands require that the controller be configured before they can be sent to the controller. Some commands have been ignored because the Repeat parameter has been specified in the input file. The system must be rebooted for the firmware A controller has been flashed with new firmware. flash to complete The new firmware requires a reboot to take effect. Unable to set the array accelerator for this The controller may not support a cache (for volume. The cache board may be missing or example, some Software RAID controllers) or the have a bad status, or the controller may not cache may be missing or defective. support a cache ACU scripting error messages Error code Error message 0 - Comment or clarification No error exists. The program completed HP Array Configuration Utility 91

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

HP Array Configuration Utility
91
<!ELEMENT Drive ( ALL | #PCDATA ) >
<!ELEMENT OnlineSpare ( YES | NO | #PCDATA ) >
<!ELEMENT LogicalDrive ( Raid, Repeat | Size, Sectors, StripeSize,
ArrayAccelerator? ) >
<!ATTLIST LogicalDrive ID PCDATA #REQUIRED >
<!ELEMENT ArrayAccelerator ( ENABLE | DISABLE ) ENABLE >
<!ELEMENT Raid (0 | 1 | 1ADM | 10 | 10ADM | 4 | 5 | 6 | ADG | 50 | 60)
>
<!ELEMENT Repeat ( MAX | #PCDATA ) >
<!ELEMENT Sectors ( 32 | 63 ) >
<!ELEMENT Size ( MAX | #PCDATA ) MAX >
<!ELEMENT StripeSize ( 8 | 16 | 32 | 64 | 128 | 256 | 512 ) >
<!ELEMENT Initiator ( HBA_WW_ID, ConnectionName?, HostMode? ) >
<!ELEMENT HBA_WW_ID ( #PCDATA ) >
<!ELEMENT ConnectionName ( #PCDATA ) >
<!ELEMENT HostMode ( #PCDATA ) >
]>
ACU scripting warning messages
Warning
code
Warning message
Comment or clarification
4000
License key is already installed
The input file specified a license key. However, a
license key is already installed on the controller.
4001
Clear configuration command failed -
configuration is already cleared
The
-reset
option was used on a controller that
does not have a configuration.
4002
Chassis name is already set to this value
The chassis name is already set to the supplied
value. The command is ignored.
4003
One or more controller commands were
skipped because the controller is not
configured
Certain commands require that the controller be
configured before they can be sent to the controller.
4004
Using Repeat function
Some commands have been ignored because the
Repeat parameter has been specified in the input
file.
4005
The system must be rebooted for the firmware
flash to complete
A controller has been flashed with new firmware.
The new firmware requires a reboot to take effect.
4006
Unable to set the array accelerator for this
volume. The cache board may be missing or
have a bad status, or the controller may not
support a cache
The controller may not support a cache (for
example, some Software RAID controllers) or the
cache may be missing or defective.
ACU scripting error messages
Error code Error message
Comment or clarification
0
No error exists. The program completed