Error reporting If errors occur in the input file, HP SUM exits with a return value of -2 (bad parameter). The details of the location and nature of the error are recorded in hpsum_execution_log__.raw. Input file parameters Parameter SILENT TARGETTYPE FORCEALL FORCEROM Description Possible values This parameter causes the installation to run silently without GUI or console output. All data is written to the log file. Any generated prompts use the default option and continue the installation without user input. YES, NO If a component requires input before installation (such as configuration information), the component installation fails (unless the IGNOREERRORS = "FailedDependencies" parameter is supplied), and an error message is written to the log file. This parameter specifies the node type /targettype vc and can shorten the inventory process. The following are valid node types: • Server • Windows • Linux • HPUX • EVA or Command View for EVA • FC Switch or Fibre Channel Switch • OA or Onboard Administrator • SUPERDOME 2 or SUPERDOME2 or Superdome 2 Onboard Administrator • iLO • VC or Virtual Connect • HP SAS or HP SAS B/L Interconnect Switch • VMware or VMware Host • iPDU or Intelligent Power Distribution Unit (iPDU) If you use the command with a group, the HP SUM assumes all nodes in the group are the same node type. Forces updates to both firmware and YES, NO software components. Forces updates to firmware components. YES, NO 50 Using legacy scripts to deploy updates

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77

Error reporting
If errors occur in the input file, HP SUM exits with a return value of –2 (bad parameter). The details
of the location and nature of the error are recorded in
hpsum_execution_log_<date>_<time>.raw
.
Input file parameters
Possible values
Description
Parameter
YES
,
NO
This parameter causes the installation
to run silently without GUI or console
SILENT
output. All data is written to the log
file. Any generated prompts use the
default option and continue the
installation without user input.
If a component requires input before
installation (such as configuration
information), the component
installation fails (unless the
IGNOREERRORS
=
"FailedDependencies" parameter is
supplied), and an error message is
written to the log file.
/targettype vc
This parameter specifies the node type
and can shorten the inventory process.
TARGETTYPE
The following are valid node types:
Server
Windows
Linux
HPUX
EVA
or
Command View for
EVA
FC Switch
or
Fibre
Channel Switch
OA
or
Onboard
Administrator
SUPERDOME 2
or
SUPERDOME2
or
Superdome
2 Onboard Administrator
iLO
VC
or
Virtual Connect
HP SAS
or
HP SAS B/L
Interconnect Switch
VMware
or
VMware Host
iPDU
or
Intelligent
Power Distribution Unit
(iPDU)
If you use the command with a
group, the HP SUM assumes all
nodes in the group are the same
node type.
YES
,
NO
Forces updates to both firmware and
software components.
FORCEALL
YES
,
NO
Forces updates to firmware
components.
FORCEROM