HP StorageWorks MSA1510i HP Storage Management Utility user guide (383075-002, - Page 31

Sample con, guration-Physical-to-logical storage diagram, Description

Page 31 highlights

Sample configuration-Physical-to-logical storage diagram 11 12 13 8 5 2 9 6 3 10 7 4 1 15293 Item Description 1 MSA1510i controller shelf and Sample includes two array controllers and two 2-Port Ethernet iSCSI modules, MSA20 storage enclosure with twelve SATA hard drives in the storage enclosure. 2 Array A Uses hard drives from bays 1, 2, 3, and 4. 3 Array B Uses hard drives from bays 5, 6, and 7, with number 11 assigned as a spare. 4 Array C 5 Logical Drive 1 6 Logical Drive 2 7 Logical Drive 3 Uses hard drives from bays 8, 9, and 10, with number 12 assigned as a spare. Uses all space from Array A, with RAID 1+0 fault tolerance. Uses all space from Array B, with RAID 5 fault tolerance. Uses all space from Array C, with RAID 5 fault tolerance. 8 Mapped Logical Drive 1 When Logical Drive 1 was mapped to this target (Target 1), it was renamed to Mapped Logical Drive 1. 9 Mapped Logical Drive 1 When Logical Drive 2 was mapped to this target (Target 2), it was renamed to Mapped Logical Drive 1. 10 Mapped Logical Drive 1 11 Target 1 12 Target 2 13 Target 3 When Logical Drive 3 was mapped to this target (Target 3), it was renamed to Mapped Logical Drive 1. HP Storage Management Utility user guide 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Sample con
guration—Physical-to-logical storage diagram
15293
1
2
5
6
7
8
9
10
11
12
13
3
4
Item
Description
1
MSA1510i controller shelf and
MSA20 storage enclosure
Sample includes two array controllers and two 2-Port Ethernet iSCSI modules,
with twelve SATA hard drives in the storage enclosure.
2
Array A
Uses hard drives from bays 1, 2, 3, and 4.
3
Array B
Uses hard drives from bays 5, 6, and 7, with number 11 assigned as a spare.
4
Array C
Uses hard drives from bays 8, 9, and 10, with number 12 assigned as a spare.
5
Logical Drive 1
Uses all space from Array A, with RAID 1+0 fault tolerance.
6
Logical Drive 2
Uses all space from Array B, with RAID 5 fault tolerance.
7
Logical Drive 3
Uses all space from Array C, with RAID 5 fault tolerance.
8
Mapped Logical Drive 1
When Logical Drive 1 was mapped to this target (Target 1), it was renamed
to Mapped Logical Drive 1.
9
Mapped Logical Drive 1
When Logical Drive 2 was mapped to this target (Target 2), it was renamed
to Mapped Logical Drive 1.
10
Mapped Logical Drive 1
When Logical Drive 3 was mapped to this target (Target 3), it was renamed
to Mapped Logical Drive 1.
11
Target 1
12
Target 2
13
Target 3
HP Storage Management Utility user guide
31