HP StorageWorks MSA1510i HP Storage Management Utility user guide (383075-002, - Page 66

Identifying devices (Identify Device), Refreshing the display (Refresh System)

Page 66 highlights

Enabling iSNS discovery of specific targets (Discovery Settings) 1. Select Target > Discovery Settings. 2. Expand the drop-down boxes to Enable SLP and/or iSNS Discovery. Identifying devices (Identify Device) To locate a system component by lighting up its LEDs, select the item from the component list, and then select Identify Device. For example, if this task is selected for a logical drive, the LEDs on the physical hard drives included in that logical drive are illuminated. Refreshing the display (Refresh System) Use this option to update the SMU display. To refresh the SMU display, select Refresh System. The utility scans the configuration and, after a few moments, updates the display. Resetting the system (Reset System) Use this option to remotely reset (power cycle) the array controller. To reset the array controller, select Storage System > Reset System. The following warning message is displayed. 66 Configure

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Enabling iSNS discovery of speci
c targets (Discovery Settings)
1.
Select
Target
>
Discovery Settings
.
2.
Expand the drop-down boxes to Enable SLP and/or iSNS Discovery.
Identifying devices (Identify Device)
To locate a system component by lighting up its LEDs, select the item from the component list, and then
select
Identify Device
.
For example, if this task is selected for a logical drive, the LEDs on the physical hard drives included
in that logical drive are illuminated.
Refreshing the display (Refresh System)
Use this option to update the SMU display.
To refresh the SMU display, select
Refresh System
. The utility scans the con
guration and, after a few
moments, updates the display.
Resetting the system (Reset System)
Use this option to remotely reset (power cycle) the array controller.
To reset the array controller, select
Storage System
>
Reset System
.
The following warning message is displayed.
66
Con
gure