HP StorageWorks MSA1510i HP Storage Management Utility user guide (383075-002, - Page 51

Security tasks, Setting up Access Control Lists

Page 51 highlights

Figure 13 Sample configuration-after adding initiators IMPORTANT: Perform the following tasks to complete the configuration: • Enter security settings (optional, but recommended). (For more information, see "Security tasks" on page 51.) • Enter configuration settings in the iSCSI initiator configuration software utility (on the server), including: • Adding target portals for the initiator to access. • Configuring the target portals. (Be sure to select the option to automatically restore the connection each time the system restarts.) • Logging on to establish an active session. Security tasks Security can include one or all of the following: • Setting up Access Control Lists • Setting up CHAP authentication • Setting the SSL certificate Setting up Access Control Lists Access control lists (ACLs) provide security at the LUN level. In an ACL, you indicate the initiator(s) that can access specific mapped logical drive units of a target. NOTE: Repeat all steps in this section for each target for which you want to establish an ACL. 1. From the server, open the iSCSI initiator software and close any active connections to the target. This ensures that there is no I/O activity on the target. HP Storage Management Utility user guide 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Figure 13 Sample con
guration—after adding initiators
IMPORTANT:
Perform the following tasks to complete the con
guration:
Enter security settings (optional, but recommended). (For more information, see
Security tasks
” on page 51.)
Enter con
guration settings in the iSCSI initiator con
guration software utility (on the server),
including:
Adding target portals for the initiator to access.
Con
guring the target portals. (Be sure to select the option to automatically restore the connection
each time the system restarts.)
Logging on to establish an active session.
Security tasks
Security can include one or all of the following:
Setting up Access Control Lists
Setting up CHAP authentication
Setting the SSL certi
cate
Setting up Access Control Lists
Access control lists (ACLs) provide security at the LUN level. In an ACL, you indicate the initiator(s) that
can access speci
c mapped logical drive units of a target.
NOTE:
Repeat all steps in this section for each target for which you want to establish an ACL.
1.
From the server,
open the iSCSI initiator software and close any active connections to the target. This
ensures that there is no I/O activity on the target.
HP Storage Management Utility user guide
51