HP StorageWorks MSA1510i HP Storage Management Utility user guide (383075-002, - Page 72

Data Port, IP Address, VLAN ID, iSCSI Target Name, iSCSI Initiator Name, SA0. HP recommends

Page 72 highlights

6. In the iSCSI Configuration page, enter values for one of the data ports. NOTE: • By default, the wizard recommends configuring Data Port SA0. HP recommends accepting the default. • Assign an IP Address to the data port. • VLANs are set up on the switch and are used as one method of controlling access to the storage. If using VLANs, enter the VLAN ID to use (0 = not used). • The wizard suggests a default iSCSI Target Name and iSCSI Target Alias. Accept the default or enter user-defined values. • Be sure to enter the iSCSI Initiator Name exactly as assigned in the iSCSI initiator software utility (on the server). Include all special characters, including periods and spaces. If the Initiator Name is entered incorrectly, the target cannot be presented to the initiator. • In dual-controller configurations, the Redundant iSCSI Configuration page is displayed, to enter settings for a data port on the redundant module. • To configure the remaining data ports, complete the Initial System Configuration Wizard process, and then use tasks available in the Configure tab. (For more information, see "Configuring management and data ports" on page 33.) 72 Wizards

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

6.
In the iSCSI Con
guration page, enter values for one of the data ports.
NOTE:
By default, the wizard recommends con
guring
Data Port
SA0. HP recommends
accepting the default.
Assign an
IP Address
to the data port.
VLANs are set up on the switch and are used as one method of controlling access to the
storage. If using VLANs, enter the
VLAN ID
to use (0 = not used).
The wizard suggests a default
iSCSI Target Name
and
iSCSI Target Alias
. Accept
the default or enter user-de
ned values.
Be sure to enter the
iSCSI Initiator Name
exactly as assigned in the iSCSI initiator
software utility (on the server). Include all special characters, including periods and
spaces. If the Initiator Name is entered incorrectly, the target cannot be presented
to the initiator.
In dual-controller con
gurations, the Redundant iSCSI Con
guration page is displayed,
to enter settings for a data port on the redundant module.
To con
gure the remaining data ports, complete the Initial System Con
guration Wizard
process, and then use tasks available in the Con
gure tab. (For more information, see
Con
guring management and data ports
” on page 33.)