HP StoreOnce D2D4324 HP StoreOnce VSA Deployment and Configuration Guide (TC45 - Page 48
Error running system show status, Data vdisks not recognized when executing the StoreOnce CLI
View all HP StoreOnce D2D4324 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 48 highlights
Error running system show status The StoreOnce CLI command, system show status, displays an additional size for the "Discovered" storage size. This is a known issue with the StoreOnce VSA and does not affect device performance or behavior. # system show status Status ------ Formatted 4,045.55GB, Adding 1,452GB... Service Sets Status Notes Set 1 Running Data vdisks not recognized when executing the StoreOnce CLI storage addition commands Cause The data virtual disks added are assigned to different SCSI controllers. Solution If the data disks have been assigned to different SCSI controllers, a reboot of the StoreOnce VSA is required to recognize them. Once rebooted, run the StoreOnce CLI command, hardware add storage to add storage. 48 Troubleshooting